Timing Data - IDEC HR6S Series Original Instructions Manual

Safety module
Hide thumbs Also See for HR6S Series:
Table of Contents

Advertisement

Timing Data

Maximum Response Times
Characteristic
Maximum response time to request at safety-related input 20 ms
Maximum response time after power outage AC
Maximum response time after power outage DC
Recovery Time
Characteristic
Recovery time after request at safety-related input
Switch-On and Activation Delays
Characteristic
Switch on delay after power on and automatic start
Delay after activation of safety-related input or valid start
condition
Monitored Start
Characteristic
Waiting time
Minimum duration of start pulse for monitored start
Dynamization of Safety-Related Inputs and Start Input
Characteristic
Test pulse duration (safety-related input must be activated
for longer than duration of test pulse)
Test pulse interval
Maximum delay of test pulse
Test pulse phase shift
HR9Z-B2190 8/2020
Value
200 ms
120 ms
Value
200 ms
Value
2500 ms
100 ms
Value
2500 ms
80 ms
Value
2 ms
500 ms
40 ms
At least 70 ms
Technical Data
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hr6s-abHr6s-ab1pHr6s-ab1c

Table of Contents