IDEC HR6S Series Original Instructions Manual page 62

Safety module
Hide thumbs Also See for HR6S Series:
Table of Contents

Advertisement

Functions
Application Function 6
Characteristic
Typical applications
Type of outputs of sensor/device providing the input signal
for application function
S## terminals to be connected
Dynamization
Signal interlock monitoring
Synchronization:
Synchronized terminals
S12 synchronized with S13
Wiring of the inputs for sensors/devices with OSSD outputs
62
Value/Description
Monitoring of electro-sensitive protective
equipment such as type 4 light curtains as per
IEC 61496-1
Monitoring of RFID sensors
OSSD (Output Signal Switching Device) outputs
S12 and S13
No
Between terminals S12 and S13
Synchronization time
S12 and S13 have to be activated within 0.5 s.