Functions
Application Function 2
Characteristic
Typical applications
Type of outputs of sensor/device providing the input signal
for application function
S## terminals to be connected
Dynamization
Signal interlock monitoring
This application function requires the start function selector to be set to positions 1 or 5, automatic
start without startup test. Refer to Start Functions
Synchronization:
Synchronized terminals
S12 synchronized with S13
Wiring of the inputs for two-hand control devices
58
Value/Description
Monitoring of two-hand control devices, type III
A as per ISO 13851
Normally open, normally closed and/or changeover
outputs
S11-S12 and S11-S13
Yes
Between terminals S12 and S22
(see page
63) for details.
Synchronization time
S12 and S13 have to be activated within 0.5 s.