Bit sequence
Description
0010110101
Input S12 is expected to
change its state. In the
case of a configuration
with antivalent inputs,
inputs S12 and S13 are
expected to change their
states.
0010110100
Input S13 is expected to
change its state.
0010101011
Waiting for startup test.
0010101010
Waiting for rising edge
for automatic/manual
start or monitored start.
0010101110
Start input activated.
Waiting for falling edge
for monitored start.
0010101111
Device in operating state
Run:Outputs Energized,
safety-related outputs
activated.
(1) Type of message: E = Error detected, A = Alert, S = Status information
HR9Z-B2190 8/2020
Correctives
-
-
-
-
-
-
Diagnostics
(1)
Type
S
S
S
S
S
S
79