Device Overview - IDEC HR6S Series Original Instructions Manual

Safety module
Hide thumbs Also See for HR6S Series:
Table of Contents

Advertisement

Introduction

Device Overview

Outline
The device is a safety module for interruption of safety-related electrical circuits.
The device provides application functions used to monitor signals from different types of
sensors/devices.
Equipment with the following types of outputs can be connected to the safety-related inputs of the
device:
NO, NC, C/O, for example, Emergency Stop push-buttons, guard door switches, coded
magnetic switches, two-hand control devices
PNP transistors, for example, magnetic switches, proximity switches
OSSD, for example, light curtains
The device is available in two different types: Push-in terminals or screw terminals.
Feature summary:
6 application functions
Configurable start function
1 safety-related inputs
2 safety-related relay outputs
1 non-safety-related status/diagnostics outputs
1 non-safety-related start input with 8 selectable start functions
16