Device Overview - IDEC HR6S-DN Instruction Manual

Safety module
Hide thumbs Also See for HR6S-DN:
Table of Contents

Advertisement

Introduction

Device Overview

Outline
The device is a safety module for interruption of safety-related electrical circuits.
The device provides application functions used to monitor signals from different types of
sensors/devices.
Equipment with the following types of outputs can be connected to the safety-related inputs of the
device:
NO, NC, C/O, for example, Emergency Stop push-buttons, guard door switches, coded
magnetic switches
PNP transistors, for example, magnetic switches, proximity switches
OSSD, for example, light curtains
The device is available in two different types: Push-in terminals or screw terminals.
Feature summary:
8 application functions
Configurable start function
6 safety-related inputs
4 safety-related relay outputs
1 non-safety-related status/diagnostics outputs
1 non-safety-related start input with 8 selectable start functions
Connector for connection of extension module HR6S-EP to increase the number of safety-
related outputs by 6
16
HR9Z-B2200 8/2020