Voltage
Voltage
12 V DC
Tolerance for voltage
- 1.5 V / + 3.0 V
Current
40 A peak
Power Consumption
Recommended tractor engine output are as follows.
Main tank volume (litres)
4500
5500
7000
• End of tractor requirements.

Temperature and Pressure Ranges

Spray Liquid System
Operating temperature range
Operating pressure for the safety valve
Max. pressure on the pressure manifold
Max. pressure on the suction manifold

Brakes

Max. wear rates on brake components:
Sprayer volume
3300 / 4500 litres
5500 / 7000 litres
Pressure settings for the load apportioning valve:
Situation
Pressure in air tank
Released
0 bar
Empty main tank
2.8 bar
Half main tank
4.3 bar
Full main tank
Max. pressure (6.5 bar)
DANGER! If one or more the values are exceeded, this may cause damages and sudden leaks on the sprayer. Risk of
injuries and fatalities.
Output (hp)
Output (kW)
115
86
130
97
150
112
2 - 40 °C
15 bar ± 1 bar
20 bar
1.5 bar
Drum dimensions
400 x 120 mm
412 x 160 mm
8 - Technical Specifications
Max. drum diameter
403 mm
414 mm
Min. lining thickness
4.5 mm
5.5 mm
163