Hours Service - Easyclean Filter; Hours Service - Cyclonefilter - Hardi COMMANDER DELTA FORCE Instruction Book

Hide thumbs Also See for COMMANDER DELTA FORCE:
Table of Contents

Advertisement

6 - Maintenance

10 Hours Service - EasyClean Filter

This filter has a clogging indicator as mentioned in the chapter
"Description", but even if this indicator does not show clogging, the filter
mostly needs cleaning every 10 hours.
Servicing the filter
1. Turn the filter lid counterclockwise to open it.
2. Remove lid and filter from the filter housing.
3. Separate filter element from lid/filter guide by turning locks (A)
outwards.
4. Clean filter and if necessary clean the housing for larger impurities.
To reassemble
1. Grease the O-ring on the filter lid.
2. Press the filter onto the filter guide/lid. Make sure that it has caught the guide. Locks (A) are turned inwards.
3. Reassemble filter/filter lid into the housing. Make sure that it has caught the guide in the bottom of the housing.
4. Turn the filter lid clockwise to close it.
±
WARNING! Always wear protective clothing and gloves before servicing the filter!
ATTENTION! If difficulties with opening the filter occur, it can then be emergency handled. See "Emergency Operation -
EasyClean filter" on page 158.

10 Hours Service - CycloneFilter

Servicing the filter
1. Turn the pressure SmartValve towards the unused function or to
tank cleaning nozzles.
2. Unscrew the filter lid (A).
3. Lift lid and filter (B) from the housing.
4. Turn the two locks (C) outwards to unlock the filter from the lid.
5. Separate filter from the integrated filter guide in the lid and clean
the filter.
To reassemble
1. Grease the two O-rings on the lid/filter guide. Due to small space
at lid, use for example a brush to apply the grease.
2. Mount the filter onto the recess (which may not be greased) in the
lid/filter guide.
3. Turn the two locks (C) inwards to lock the filter to the lid.
4. Place the filter/filter lid into the housing and screw the lid, until it hits the stop.
±
WARNING! Always wear protective clothing and gloves, before servicing the filter!
DANGER! The pressure SmartValve must always be turned to the unused function or to tank cleaning nozzles before
opening the CycloneFilter! If not, the spraying liquid can hit you, when opening the filter, and the main tank content
will drain away!
122