Lubrication After Assembly
After disassembling the pump (diaphragm renewal, etc.), the pump
MUST be lubricated with 200 g grease into each lubrication point.
HARDI pump grease cartridge (400g): HARDI item no. 28164600
Overhaul Kit
Pump model: 464.
Diaphragm pump overhaul kit (valves, seals, diaphragms etc.) can be
ordered. Detect the pump model - the overhaul kit can be ordered by
your local dealer.
Model 464: HARDI item no. 75586000.

Speed Transducer for Pump

The speed transducer, measuring rounds per minute (rpm), is located at
the inner side of the PTO shield. This sensor is an inductive type, which
requires metallic protrusions to pass by it to trigger a signal.
Adjustment
1. Adjust air gap (A) to 4 mm (+/-0.5 mm). Use a feeler gauge or
similar tool.
2. After adjustment, turn the pump shaft. Verify air gap variations less
than +/-0.5 mm. Check this at the entire circumference.
3. Verify transducer function:
• HC 5500:
Correct fitting is indicated by continuous flashing from
transducer, when the shaft is rotating.
• HC 6500/ISOBUS VT:
Monitor the menu [4.5.4.9.6 PTO pump frequency].