8 - Technical Specifications

Temperature and Pressure Ranges

Spray Liquid System
Operating temperature range
Operating pressure for the safety valve
Max. pressure on the pressure manifold
Max. pressure on the suction manifold

Brakes

Max. wear rates on brake components:
Sprayer volume
4500 litres
5500 / 7000 litres
Pressure settings for the load apportioning valve:
Situation
Pressure in air tank
Released
0 bar
Empty main tank
2.8 bar
Half main tank
4.3 bar
Full main tank
Max. pressure (6.5 bar)
DANGER! If one or more the values are exceeded, this may cause damages and sudden leaks on the sprayer. Risk of
injuries and fatalities.

Filters

The higher the number of mesh, the finer the filtration.
Size of openings in
Mesh
the filter
18
1.00 mm
30
0.58 mm
50
0.30 mm
80
0.18 mm
100
0.15 mm
*depending on selected nozzles
**not with PrimeFlow system
200
2 - 40 °C
15 bar ± 1 bar
20 bar
1.5 bar
Drum dimensions
400 x 120 mm
412 x 160 mm
Color
EasyClean
White
-
Green
Yes
Blue
Yes
Red
Yes
Yellow
-
Max. drum diameter
403 mm
414 mm
Filter name / position
Cyclone
In-Line**
-
-
-
Yes
-
Min. lining thickness
4.5 mm
5.5 mm
Tank strainer
-
Yes
-
-
Yes*
-
Yes*
-
Yes*
-
Nozzle
-
-
Yes*
Yes*
Yes*