Lubrication After Assembly
After disassembling the pump for diaphragm renewal, etc., the pump
MUST be lubricated with 200 g grease into each lubrication point.
HARDI pump grease cartridge (400g): HARDI item no. 28164600
Overhaul Kit
Pump model: 464.
Diaphragm pump overhaul kit (valves, seals, diaphragms etc.) can be
ordered. Detect the pump model - the overhaul kit can be ordered by
your local dealer.
Model 464: HARDI item no. 75586000.

BoomPrime One-Way Valve

If the one-way valves for the BoomPrime system are clogged, they must
be cleaned.
1. Disassemble the two parts.
2. Clean the parts as needed.
3. Check the state of the black O-ring (A).
4. Assemble the parts again and tighten with a torque of 1 Nm.
μ
ATTENTION! If any part is worn or damaged, it should be replaced.

Speed Transducer for the Pump

The speed transducer that measures rotations per minute (RPM), is
located at the inner side of the PTO shield.
The sensor is an inductive type, which requires metallic protrusions to
pass by it to trigger a signal.
If the sensor is exchanged, it must installed accurately to function
properly.
Adjustment
1. Adjust the air gap (A) between sensor tip and the protruding
pump part by turning the counter nuts at the support bracket for
the sensor.
The air gap (A) must be set to 1 mm (+0.3/-0.0 mm).
Use a feeler gauge or similar tool to verify.
2. Verify transducer function on the controller:
• SmartCom:
Monitor the menu [4.3.5.1.3 Pump RPM].