Removal and Installation Procedures
CH2 OUT10G Board
4-36
The cable at J120 from the CH1 OUT10G board to the Channel 1 Mkr 1
connector.
The cable at J130 from the CH1 OUT10G board to the Channel 1 Mkr 1
connector.
The cable at J160 from the CH1 OUT10G board to the Channel 1 Mkr 2
connector.
The cable at J190 from the CH1 OUT10G board to the Channel 1 Mkr 2
connector.
7. Remove the four screws securing the CH1 OUT10G board to the chassis.
8. Lift the board away from the chassis.
Installation. To install, reverse this procedure.
You need a screwdriver with a T-15 Torx tip and pliers (items 1, 2, and 8).
Removal. To remove the CH2 OUT10G board, refer to Figure 4-13 on page 4-28
and follow these steps:
1. Remove the handle unit, snaps, cosmetic covers, front-trim unit, EMI covers,
relay unit (for Option 02 or 06), and AWG10G board.
2. Orient the instrument so that the top is on the work surface.
3. Remove the five screws securing the shield bracket to the chassis.
4. Lift the bracket away from the chassis.
5. Disconnect the ribbon cable at J500 from the CH2 OUT10G board.
6. Disconnect these cables:
For Option 02 or 06, there are no cable connections at J600 and J700 on
NOTE.
the CH2 OUT10G board.
The cable at J600 from the CH2 OUT10G board to the AWG10G board
(J100B).
The cable at J700 from the CH2 OUT10G board to the AWG10G board
(J101B).
The cable at J100 from the CH2 OUT10G board to the AWG10G board
(J110B).
The cable at J110 from the CH2 OUT10G board to the AWG10G board
(J111B).
The cable at J150 from the CH2 OUT10G board to the AWG10G board
(J115B).
The cable at J170 from the CH2 OUT10G board to the AWG10G board
(J116B).