Platform: DBALL2
Firmware: CHRYSLER Remote Start Ready (RSR) Installation
LED Diagnostics & Troubleshooting
LED
Status
Module Programming
Off
Off
Solid red
Solid red
Flashes
Flashes orange
orange
Flashes green
Flashes
green
Solid green for 3
Solid green
x3 secs
seconds
Solid orange for 3
Solid orange
x3 secs
seconds
Active Ground While Running
Flashes green
Flashes
green
Flashes
red &
Flashes red & orange
orange
Flashes
Flashes green quickly
green
quickly
Inactive Ground While Running
Flashes
Flashes orange x1
orange x1
Flashes orange x2
Flashes
orange x2
Flashes
Flashes orange x3
orange x3
Flashes
Flashes orange x4
orange x4
Flashes
Flashes orange x5
orange x5
External Module Synchronization
Flashes red, red and
(Flashes red,
orange x10
red, then
orange) x 10
RSR Code
Flashes red
Flashes red x 7
x7
Description
Module has no power.
The bus type cannot be detected.
The vehicle type cannot be
detected.
Waiting for keyless.
Module was successfully
programmed or is already
programmed.
Module was successfully
programmed without diagnostics.
GROUND OUT ON (GWR)
command received.
IGNITION ON command received.
START ON command received.
Lock command has been received
Unlock command has been
received
Trunk command has been received
AUX1 command has been received
AUX2 command has been received
OBDII feature not supported.
Diagnostic data bus not detected.
3x OEM Lock Remote Start
Activation was attempted when
RFTD feature is disabled.
Troubleshooting
Check the power connections.
Make sure the connections to the data bus are correct and
insert the key in the ignition switch.
Insert the key in the ignition switch and turn to the ON position.
You may need to wait up to 10 seconds.
Remove the key from the ignition switch and press a keyless
button.
Normal operation.
Normal operation.
Otherwise, the Ground While Running (status) signal
was lost or was never received by the module.
Commands can come from RF, D2D or W2W.
Otherwise, the ignition signal was not received by the
module. In a W2W install, it will show only if the ignition
input wire is used.
Otherwise, the start signal was not received by the
module. In a W2W install, it will show only if the ignition
input wire is used.
Normal operation.
Some features are not supported by SmartStart. This can be
caused by missing wire connections or module hardware
limitation. Refer to the wiring installation section to check the
connections.
Activated from Web automatically when using RSR flash tool or
can be done manually. Refer to feature programing section for
more information.
Rev.: 20160908