Feature Programming - Directed Xpresskit DBALL2 Manual

Hide thumbs Also See for Xpresskit DBALL2:
Table of Contents

Advertisement

Platform: DBALL2
Firmware: CHRYSLER Remote Start Ready (RSR) Installation

Feature Programming

To enter feature programming routine
Turn the ignition ON, then OFF.
Within 5 seconds, press and HOLD the programming button until the LED turns ON orange (after 3 seconds). Release the
Programming button.
The LED will flash green once slowly to indicate the feature number is 1. After a short delay, the LED flashes red rapidly to indicate
the current option of feature 1 (i.e. 1x green followed by 1x red indicates feature 1 is set to option 1). The flashing sequence will
repeat until a new command is entered.
Changing feature options
Press the lock/arm or unlock/disarm button on aftermarket transmitter to change the option of the selected feature. When installing the
DBALL2 in RSR using 3x OEM Lock Remote Start Activation only, there is no aftermarket transmitter on which to press lock/unlock to
change the options of the selected feature. Tapping the green or blue lock/unlock wires on the black 10-pin harness to ground will
change the option for the selected feature.
The LED flashes red rapidly the number of times equal to the current option number. After a short delay, the LED flashes green slowly
the number of times to indicate the current feature. The flashing sequence will repeat until a new command is entered.
Accessing another feature
Press and release the programming button a number of times to advance from the current feature to the next desired feature.
The LED flashes green slowly the number of times equal to the feature number. After a short delay, the LED flashes red rapidly to
indicate the current option of the current feature. The flashing sequence will repeat until a new command is entered.
When the maximum number of features or options is reached, the LED will start flashing again from the first feature or option.
Once a feature is programmed
Other features can be programmed.
The feature programming can be exited.
Exiting feature programming
No activity for 30 seconds; after 30 seconds, the LED will turn ON orange for 2 seconds to confirm the end of the programming
sequence.
OR
Press and HOLD the programming button for 3 seconds. After 3 seconds, the LED will turn ON orange for 2 seconds to confirm the
end of the programming sequence.
Rev.: 20160908
Page 22
Programming
Button
© 2016 Directed. All rights reserved.

Advertisement

Table of Contents
loading

Table of Contents