GSM - Configure and monitor GSM/GPRS module operation mode
RTN - Configure and monitor Virtual reference station operation mode
DATAMODE - Exit Command Mode
[COMMAND] /? - Display Command Usage
4.3. SAVE
The SAVE command is intended to store the unit's currently used configuration into the User
Configuration file. The configuration stored in the User Configuration file is activated automatically after
unit's reboot.
4.4. SLEEP
The SLEEP command determines the sleep mode parameters. The sleeping HPT404BT with GSM can be
activated by real-time CLK, DTR/RTS lines, and command received through TTL inputs. The user can
select one, two, or all three conditions.
SLEEP [Parameter Name] [Parameters List] [/?]
Parameter Name
CLK
HW
TTL
GTS
5. Diagnostics and Identification Commands
5.1. INFO
The INFO command is used to retrieve the Radio ID along with its Hardware version, the loaded real-
time software version/revision and BootLoader's version/revision.
INFO [Parameter Name] [Parameters List] [/?]
Parameter Name
ID
SN
HW
www.javad.com
0 – Do not activate by internal real-time clock
(1 – 255) – Activate by internal real-time clock after 100 to 25500 msec of sleeping
0 – Do not activate through DTR/RTS lines
1 – Activate through DTR/RTS lines
0 – Do not activate by external sense lines
1 – Activate by external sense lines
0 – Disable Sleep mode (default)
(1 – 255) – Go to sleep mode if there is no activity in 10 to 2550 msec
Product ID:
ID47 - HPT404BT_GSM
Six bytes Serial Number (SN)
1.0 - hardware version in numeric "Major.Minor" format
Diagnostics and Identification Commands