Advertisement

Quick Links

HPT401BT
User Manual
Version 1.0
Last Revised June 24, 2014
All contents in this manual are copyrighted by JAVAD GNSS.
All rights reserved.The information contained herein may not be used, accessed, copied,
stored, displayed, sold, modified, published, or distributed, or otherwise reproduced without express written
consent from JAVAD GNSS

Advertisement

Table of Contents
loading

Summary of Contents for Javad HPT401BT

  • Page 1 Version 1.0 Last Revised June 24, 2014 All contents in this manual are copyrighted by JAVAD GNSS. All rights reserved.The information contained herein may not be used, accessed, copied, stored, displayed, sold, modified, published, or distributed, or otherwise reproduced without express written...
  • Page 2 © JAVAD GNSS Inc., 2014 www.javad.com...
  • Page 3: Table Of Contents

    3. Connecting HPT401BT and Computer ........
  • Page 4 Appendix C. Warranty Terms ..........35 www.javad.com...
  • Page 5: Preface

    Please read these Terms and Conditions carefully. Terms and Conditions USE – JAVAD modems are designed to be used by a professional. The user is expected to have a good knowledge and understanding of the user and safety instructions before operating, inspecting or adjusting.
  • Page 6: Regulatory Information

    Conditions. The user is granted a personal, non-exclusive, non-transferable license to use such Software under the terms stated herein and in any case only with a single HPT401BT or single computer. You may not assign or transfer the Software or this license without the express written consent of JAVAD. This license is effective until terminated.
  • Page 7: Manual Conventions

    This manual uses the following conventions: Example Description  Click the File menu and click Exit File Exit Link Space This format represents titles of dialog windows/boxes, names of menu options, identifies program interface objects, such as checkboxes, edit boxes, radio buttons, etc. www.javad.com...
  • Page 8: Screen Captures

    This is normal and not a cause for concern. Technical Assistance If you have a problem and cannot find the information you need in the product documentation, contact your local dealer. www.javad.com...
  • Page 9: Chapter 1. Introduction

    The built-in software tools provide the wireless link testing, unit’s status and error statistics monitoring as well as unit’s settings change over the air. The firmware of the HPT401BT radio modem resides in a flash memory. The updating of the radio modem programs is entirely software-based. The flash memory is re- programmable through an RS-232 interface, USB, or Bluetooth.
  • Page 10: Getting Acquainted

    Getting Acquainted 1. Getting Acquainted The HPT401BT is a rugged and very powerful external radio transceiver 5.75 x 2.95 x 1.73 inches (146 x 75 x 44 mm), 488 kg); HPT401BT with battery dimensions are 3.11 x 5.94 x 2.87 inches weighs 1.3 lbs (0.
  • Page 11: External Antenna Connector And Bluetooth Antenna

    The mounting bracket connects the modem to a standard pole/adapter. 1.5. Cables The HPT401BT package includes standard communication and power cables for configuring the modem and providing a power source to the modem. • AC Power Adapter, 3c, C13 / NEMA 5-15P, USA •...
  • Page 12: Storage Precautions

    3. Use a clean cloth, moistened with a neutral detergent or water, to clean the modem. Never use an abrasive cleaner, ether, thinner benzene, or other solvents. Always make sure the instrument is completely dry before storing. Dry the modem with a soft, clean cloth. www.javad.com...
  • Page 13: Chapter 2. Configuration

    1.1. Power supply requirements A single external power supply is necessary to operate HPT401BT. The external power supply needs to be Listed for US and Certified for EU countries, it needs also to be a Limited Power Source and rated for Outdoor Use and have an output rated for +12...
  • Page 14: Antenna Installation

    Use ModemVU to load new firmware to the modem. 3.1. Connecting through serial port To configure, or maintain HPT401BT, you need to connect the modem and a computer using an Data-Ser- Pwr Cable, DB9/DB15/SAE (1,8m) p/n 14-578108-02. . Figure 2. Accessory Data-Ser-Pwr Cable Default parameters for Serial port are: •...
  • Page 15: Connecting Through Usb Port

    Make sure the computer has special USB driver installed (available from www.javad.com) before continuing. To configure, or maintain HPT401BT using USB port, you need to connect the modem and a computer using special cable Access Data-Ser Cable, USB/DB15/SAE (1,8m) (p/n 14-578123-02).
  • Page 16: Configuring Hpt401Bt

    Configuration Configuring HPT401BT HPT401BT and external device connection procedure varies slightly depending on the type of external device used. In general, the connection procedure is as follows: ® Note: Refer to your Bluetooth -enabled external device documentation for more detailed connection information.
  • Page 17: Checking Firmware Version

    Identification tab shows versions of HPT401BT components: Figure 6. Identification tab This tab lists important information about the hardware accessories and software properties. This list includes the following, which you will need if you contact JAVAD GNSS Communications or your dealer: • Unit Type...
  • Page 18: New Firmware Downloading

    3. Click Download FW MCU, select the file with the new MCU firmware and click OK. 4. Use the latest firmware version, available for download from the JAVAD GNSS website www.javad.com, to ensure your modem has the most recent updates.
  • Page 19: Chapter 3. Command Line Interface

    SAVE command must be asserted. • [/?] orders to show the help information for the given command. • Commands are not key sensitive; small, none capital characters can be used to enter CLI commands. www.javad.com...
  • Page 20: Software Switching To Maintenance Mode

    (i.e. transmits data received from DTE over the air – including the just received, unexpected, data and forwards data received over the air to DTE.) 1.2. Switching to Data Mode • DTE sends the CLI command “DATAMODE<CR>” or „DATAMODE<LF>” to the unit. www.javad.com...
  • Page 21: Software Switching To Data Route Mode

    Figure 1: Unit Serial Number Connect 003578659922 003574459923 Figure 1. Connection List To disconnect from the remote unit and connect to the local unit, the parameter (Unit_Numb) must be equal to 0x00. www.javad.com...
  • Page 22: Link

    (15 – 30) / (30 – 1000) – RF output Power in dBm / mW 0 – No Retransmission in the wireless cluster 1 – There is Repeater in the wireless cluster, valid for Base only SCRAM 0 – No Scrambling (a default setting) (1 – 255) – Seed for Pseudo-Random Sequence Generator www.javad.com...
  • Page 23: Serial Interfacing Commands

    1 – 1200 baud 2 – 2400 baud 3 – 4800 baud 4 – 9600 baud 5 – 14400 baud 6 – 19200 baud 7 – 38400 baud 8 – 57600 baud 9 – 115200 baud, a default setting www.javad.com...
  • Page 24: Mport

    The ALARM command is intended to set up the alarm indication mode and alarm control lines’ behavior. ALARM [Parameter Name] [Parameters List] [/?] Parameter Name Parameter List TTL1 0 – TTL_OUT1 = logic “1” 1 – TTL_OUT1 = TTL_IN, received from remote unit (default settings) www.javad.com...
  • Page 25: Boot

    CONNECT – Connect to Specified Unit STATE – Display Status and Statistics SAVE – Save Current Configuration into Configuration File INFO – Display Product ID along with Hardware/Software Versions DATAMODE – Exit Maintenance Mode [COMMAND] /? – Display Command Usage www.javad.com...
  • Page 26: Save

    Ver. 1.0 Rev. A – displays BootLoader’s version in numeric “Major.Minor”format and revision in numeric format (range from 01 to 99) for engineering releases and alphabetic format (A to Z) for manufacturing releases The INFO command without Parameter Name indicates all values: www.javad.com...
  • Page 27: State

    BER = < 2.3E-5 FREQ = 140.000000 MHz CHAN = 10 TEMP = 70C SYNC = 1 MODE = FIXED Note: The indicated receive signal strength (RSSI) is equal to -147 dBm if there is no signal received from transmitter. www.javad.com...
  • Page 28 Command Line Interface Diagnostics and Identification Commands www.javad.com...
  • Page 29: Appendix A. Specifications

    Serial port configurable as RS-232 or RS-422, or RS-485 USB 2.0 device port Bluetooth Bluetooth V2.0 Class 2 supporting SPP Slave and Master Profiles Bluetooth Antenna Embedded Battery One embedded, 7.2V, 5850 mAh Operation Time (battery-powered) 6 hours (typ.) www.javad.com...
  • Page 30: Environmental Specifications

    Part §90.210 (C, D, E) (USA, Canada) 25/20/12.5 kHz CB 60 dBc (EU)) Spurious Emission (Conducted) -36 dBm (9 kHz – 1GHz) -30 dBm (1GHz – 4 GHz) Spurious Emission (Radiated) -36 dBm (9 kHz to 1 GHz) -30 dBm (1 GHz to 4 GHz www.javad.com...
  • Page 31: Radio Receiver

    ETSI EN 300 113-2; ETSI EN 301 489-5 EN 60950-1:2006 2. Connector Specifications 2.1. DB15 Connector This connector provides DB15 connectivity for the HPT401BT with a DB9 for connection to a PC/CE Device for configuration. Figure 1. DB15 Fem Connector www.javad.com...
  • Page 32: External Antenna Rf Connector

    Specifications Connector Specifications Note: About using and configuration RS-485 please contact JAVAD GNSS support. Table 6. DB15 Connector Specifications Number Signal Name Details DCD_OUT Data Carrier Detect (RS-232) DTR_OUT Data Terminal Ready (RS-232) RX+/CTS_IN Receive Data positive line (RS-422)/ Clear to Send (RS-232)
  • Page 33: Appendix B. Safety Warnings

    • Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, shall be placed on the apparatus. 1. General Warnings HPT401BT is a wireless device used in a mobile application, at least 100 cm from any body part of the user or nearby persons. Note: Minimum separation distance of 100 cm between the antenna and persons must be maintained.
  • Page 34 Safety Warnings General Warnings www.javad.com...
  • Page 35: Appendix C. Warranty Terms

    JAVAD GNSS’ Authorized Dealers During the warranty period, JAVAD GNSS will, at its option, repair or replace this product at no additional charge. Repair parts and replacement products will be furnished on an exchange basis and will be either reconditioned or new.
  • Page 36 900 Rock Avenue, San Jose, CA 95131 USA Phone: +1(408)770-1770 Fax: +1(408)770-1799 www.javad.com Copyright © JAVAD GNSS, Inc., 2014 All rights reserved. No unauthorized duplication.

Table of Contents