SIDOOR functions

4.1 Basic functions

Functions
CANopen maintenance data
support.industry.siemens.com/cs/ww/en/ps/18268/man)
Light barrier
Light barrier (Page 63)
Light barrier and DCPS cannot be implemented at the same time.
1)
2)
Emergency power mode and light barriers with feedback contact cannot be implemented simultaneously.
4.1
Basic functions
The basic functions described below are always available when using a SIDOOR controller.
4.1.1

Learn run

Description of function
A learn run is used to determine and store the characteristics of a particular system.
Risk of injury due to persons present in the range of motion
If persons are present in the range of motion during the learn run, there is a considerable risk
of injury due to the increased forces and energies on the doors.
Therefore, secure the door area during the learn run. This will prevent unauthorized persons
from entering the range of motion of the doors.
Note
If a DCP sensor is used, the position of the DCP sensor is determined during the learn run.
If the DCP sensor position is changed, a new learn run must be carried out.