7.3.5

Technical specifications

Article number
General information
Product version
Installation type/mounting
Mounting type
Supply voltage
permissible range, lower limit (AC)
permissible range, upper limit (AC)
relative symmetrical tolerance of the supply volt‐
age
Line frequency
Mains filter
Input current
Current consumption, max.
Operational current of fuse protection at input,
min.
Operational current of fuse protection at input,
max.
Tripping characteristic class of fuse protection at
input
Output voltage
RMS value (pulsating DC voltage at full load)
RMS value (pulsating DC voltage at full load),
min.
RMS value (pulsating DC voltage at full load),
max.
RMS value (pulsating DC voltage at 0.7 mA peak
current), max.
Power
Emitted active power, max.
Standards, approvals, certificates
CE mark
EAC (formerly Gost-R)
RoHS conformity
China RoHS compliance
Standard for EMC
Standard for safety
Ambient conditions
Ambient temperature during operation
AT40 and ATD400V for elevators
System Manual, 06/2022, A5E42192709-AH
permissible range, lower limit
permissible range, upper limit
integrated
7.3 SIDOOR TRANSFORMER UL
6FB1112-0AT21-2TR0
Power supply unit for SIDOOR controllers
Hexagon head bolt M6, L > 70 mm
220 V
240 V
10 %
50 Hz
60 Hz
Yes
1.6 A
6 A
10 A
D6, C10
17.3 V; at 230 V AC
16.5 V
18 V
27 V; At 264 V AC
115 W; Average value above 10 s
Yes
Yes
Yes
Yes
EN 12015 / EN 12016 / EN 61000-6-2 / EN
61000-6-3 / EN 61000-3-2 / EN 61000-3-3
UL 61010-1, CSA C22.2 No. 61010-1-12, Low Volt‐
age Directive (LVD) 2014/35/EU
Power supply