7. Press the switch while the lamp is blinking (blinking lasts for 10 seconds).
NOTE: If you do not need to perform manual regeneration, do not press the switch. The lamp will stop blinking and
go out after 10 seconds. The following message is displayed again.
Push DPD switch to activate
8. Manual regeneration starts.
• The orange lamp is lit.
• The buzzer sounds for 2 seconds.
• The following messages are displayed cyclically.
Manual DPD Re-gen
Do not operate
Regeneration time: 20 to 25 minutes.
9. Manual regeneration is complete.
• The gauge becomes zero.
• The lamp goes out.