5.4.10 Stopping status

S
Warnings
R Are shown on the screen
A Shutdowns
R To shutdown status (see
section 5.4.12)
A Stopping procedure has
R If manual start:
ended
To Ready for Start status
(see section 5.4.2)
If automatic start:
To Standby status (see
section 5.4.3)
If Power OFF:
End of operation
A Emergency Stop button
R To emergency Stop
status (see section 5.4.13)
A ↓-button, press once
R Set pressure - 0.1 bar
A ↑-button, press once
R Set pressure + 0.1 bar
A ↓-button, press
R Set pressure - 0.1 bar/
continuously
second
A ↑-button, press
R Set pressure + 0.1 bar/
continuously
second
Other actions and signals have no effect in this status.

5.4.11 Start failure status

First a stopping procedure is executed, and the
operator has to wait.
Sreen A: Start failure, origin in Permissive start
status.
- 46 -
Sreen B: Start failure, origin in Cranking status.
S
Warnings
R Are shown on the screen
A Emergency Stop button
R To emergency Stop
status (see section 5.4.13)
A ↓-button, press once
R Set pressure - 0.1 bar
A ↑-button, press once
R Set pressure + 0.1 bar
A ↓-button, press
R Set pressure - 0.1 bar/
continuously
second
A ↑-button, press
R Set pressure + 0.1 bar/
continuously
second
A Power OFF switch
R End of operation
A Reset button
R To Ready for Start status
(see section 5.4.2)
Other actions and signals have no effect in this status.