7.6.1 Installation Locations of Internal Hard Disk Units

Install the internal hard disk unit in a 3.5-inch storage bay at the front of server. Up to six units can be installed.
When an internal backup device is installed, a maximum of four internal hard disk units can be installed.
Bay 3
Bay 2
Bay 1
7.6.2 Installable Internal Hard Disk Units and the
Installation Order
■ Installable internal hard disk unit
Product name
Internal hard disk unit - 73GB
Internal hard disk unit - 147GB
Before installing an internal hard disk unit, see "B.3 Internal Hard Disk Units" ( pg.293) to check the
packaged product.
■ Installation Order
Install the internal hard disk units in the 3.5-inch storage bays in the following order.
Status of the 3.5-inch storage bay
Standard installation
When an internal backup device is
installed
table: List of installable hard discs
Model
PG-HDB75A
PG-HDB45A
table: Installation order of internal hard disk units
Bay 1 → Bay 2 → Bay 3 → Bay 4 → Bay 5 → Bay 6
Bay 1 → Bay 4 → Bay 5 → Bay 6
PRIMERGY RX300 S3 User's Guide
Bay 6
Bay 5
Bay 4
Overview
73.4GB, 15,000rpm, SAS
3.5-inch, hot plug support
146.8GB, 15,000rpm, SAS
3.5-inch, hot plug support
Installation order
7