Table 9-30 Rtrv-Alm-All Syntax Description - Cisco 15216 EDFA2 Operation Manual

Cisco systems optical network system operations guide
Table of Contents

Advertisement

TL1 Commands and Autonomous Messages
Syntax
RTRV-ALM-ALL:[<tid>]::<ctag>::[<ntfcncde>],[<condtype>],[<srveff>][,,,,,];
<sid> <date> <time>
M
<ctag> COMPLD
"<aid>,<ccm>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,:<conddescr>"
;
Example 9-25 RTRV-ALM-ALL Command and Response
Amp01:ONS15216 EDFA2> RTRV-ALM-ALL:Amp01::229::MN,LCRNT1,NSA,,;
Amp01 2002-06-20 14:30:00
M
229 COMPLD
"1,DWDM:MJ,LOS,SA,6-20,14-25-30,,:\"Loss Of Signal\""
"EQPT,EQPT:MN,LCRNT1,NSA,6-20,14-25-30,,:\"Excessive Pump1 Current\""
;

Table 9-30 RTRV-ALM-ALL Syntax Description

Parameter
aid
conddescr
condtype
(ccm)
date
Cisco ONS 15216 EDFA2 Operations Guide
9-34
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Syntax
1
EQPT
LOS
(DWDM)
GAIN
(DWDM)
LPOUT
(DWDM)
CTMP
(EQPT)
LCRNT1
(EQPT)
LCRNT2
(EQPT)
LTMP1
(EQPT)
LTMP2
(EQPT)
yyyy-mm-dd
Description
Possible values are:
Directly affecting the optical signal
General parameters of the ONS 15216 EDFA2 (not directly
affecting optical signal or power bus)
Detailed text description of the event. The conddescr is 1 to 64
characters of ASCII text. See condtype below
Condition type identifies the type of alarm (maps to
cerent15216EdfaLogEventID). Possible condtype and
corresponding conddescr (in quotes) are:
"Loss of Signal" (input power) alarm
(cerent15216EdfaAlarmLpin).
"Gain Out of Range" alarm (cerent15216EdfaAlarmGain).
"Loss of Output Power" alarm (cerent15216EdfaAlarmLpout).
"Case Temperature Out of Range" alarm
(cerent15216EdfaAlarmCtmp).
"Excessive Pump1 Current" alarm
(cerent15216EdfaAlarmLcrnt1).
"Excessive Pump2 Current" alarm
(cerent15216EdfaAlarmLcrnt2).
"Excessive Pump1 Temperature" alarm
(cerent15216EdfaAlarmLtmp1).
"Excessive Pump2 Temperature" alarm
(cerent15216EdfaAlarmLtmp2).
Date of origination of TL1 message.
Chapter 9
TL1 Commands
78-16033-01