Set Alarm Thresholds
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Figure 8-1
-48V A
Alarms are reported for the following conditions:
Degradation of electrical power source
•
Laser pump overheating or excessive pump current
•
Loss or degradation of optical input (signal)
•
Loss of output power or gain out of range
•
•
Case temperature out of range
Alarms can be connected to a NOC NMS via a network element miscellaneous discrete input and/or
office alarm panel/system.
For a full description of alarm threshold command attributes, refer to
To display the alarm thresholds, use the RTRV-TH-DWDM and RTRV-TH-EQPT commands (see
"RTRV-TH-DWDM" section on page 9-55
the following syntax:
RTRV-TH-DWDM:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,][,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>,DWDM:<thresholdtype>,,,<thresholdvalue>"
RTRV-TH-EQPT:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,][,];
<sid> <date> <time>
M
<ctag> COMPLD
"<aid>:<thresholdtype>,,,<thresholdvalue>"
Example 8-8
Example 8-8
sidtidname:ONS15216 EDFA2> RTRV-TH-DWDM::ALL:124;
sidtidname 2002-07-11 11:15:19
M
124 COMPLD
"1,DWDM:LOSTH,,,-3000"
"1,DWDM:LOSHYST,,,5"
"1,DWDM:LPOUTDEV,,,1000"
"1,DWDM:LPOUTHYST,,,5"
"1,DWDM:LPOUTSETPT,,,0"
;
sidtidname:ONS15216 EDFA2> RTRV-TH-EQPT::ALL:125;
Cisco ONS 15216 EDFA2 Operations Guide
8-6
ONS 15216 EDFA2 Front Panel
Fiber
Fiber
input
output
port
port
R A
-48V A
Fiber
Power
RET A
output
monitor
warning
port
shows sample command outputs.
Displaying the Alarm Thresholds Using TL1
Status
LEDs
POWER
FAIL
RS-232
CISCO ONS 15216
LOS
RS-232
level
(EIA/TIA-232)
and
"RTRV-TH-EQPT" section on page
Chapter 8
Provisioning Using TL1
Alarm
out
-48V B
ALARM OUT
LAN
R B
LAN port
-48V B
LAN LEDs
RET B
Chapter 9, "TL1 Commands."
9-57) according to
78-16033-01