Set Alarm Thresholds

F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Figure 8-1
-48V A
Alarms are reported for the following conditions:
Degradation of electrical power source
Laser pump overheating or excessive pump current
Loss or degradation of optical input (signal)
Loss of output power or gain out of range
Case temperature out of range
Alarms can be connected to a NOC NMS via a network element miscellaneous discrete input and/or
office alarm panel/system.
For a full description of alarm threshold command attributes, refer to
To display the alarm thresholds, use the RTRV-TH-DWDM and RTRV-TH-EQPT commands (see
"RTRV-TH-DWDM" section on page 9-55
the following syntax:
RTRV-TH-DWDM:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,][,];
<sid> <date> <time>
M <ctag> COMPLD
"<aid>,DWDM:<thresholdtype>,,,<thresholdvalue>"
RTRV-TH-EQPT:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,][,];
<sid> <date> <time>
M
<ctag> COMPLD
"<aid>:<thresholdtype>,,,<thresholdvalue>"
Example 8-8
Example 8-8
sidtidname:ONS15216 EDFA2> RTRV-TH-DWDM::ALL:124;
sidtidname 2002-07-11 11:15:19
M
124 COMPLD
"1,DWDM:LOSTH,,,-3000"
"1,DWDM:LOSHYST,,,5"
"1,DWDM:LPOUTDEV,,,1000"
"1,DWDM:LPOUTHYST,,,5"
"1,DWDM:LPOUTSETPT,,,0"
;
sidtidname:ONS15216 EDFA2> RTRV-TH-EQPT::ALL:125;
Cisco ONS 15216 EDFA2 Operations Guide
8-6
ONS 15216 EDFA2 Front Panel
Fiber
Fiber
input
output
port
port
R A
-48V A
Fiber
Power
RET A
output
monitor
warning
port
shows sample command outputs.
Displaying the Alarm Thresholds Using TL1
Status
LEDs
POWER
FAIL
RS-232
CISCO ONS 15216
LOS
RS-232
level
(EIA/TIA-232)
and
"RTRV-TH-EQPT" section on page
Chapter 8
Provisioning Using TL1
Alarm
out
-48V B
ALARM OUT
LAN
R B
LAN port
-48V B
LAN LEDs
RET B
Chapter 9, "TL1 Commands."
9-57) according to
78-16033-01