Cisco 15216 EDFA2 Operation Manual
Cisco 15216 EDFA2 Operation Manual

Cisco 15216 EDFA2 Operation Manual

Cisco systems optical network system operations guide
Table of Contents

Advertisement

Quick Links

F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Cisco ONS 15216 EDFA2
Operations Guide
Product and Software Release 2.3
August 2003
Corporate Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 526-4100
Text Part Number: 78-16033-01

Advertisement

Table of Contents
loading

Summary of Contents for Cisco 15216 EDFA2

  • Page 1 F I N A L D R A F T - C I S C O C O N F I D E N T I A L Cisco ONS 15216 EDFA2 Operations Guide Product and Software Release 2.3 August 2003 Corporate Headquarters Cisco Systems, Inc.
  • Page 2 OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. CCIP, CCSP, the Cisco Arrow logo, the Cisco Powered Network mark, the Cisco Systems Verified logo, Cisco Unity, Follow Me Browsing, FormShare, iQ Net Readiness Scorecard, Networking Academy, and ScriptShare are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, The Fastest Way to Increase Your Internet Quotient, and iQuick Study are service marks of Cisco Systems, Inc.;...
  • Page 3: Table Of Contents

    2.1.2 Channel Loading 2.2 Electrical Specifications 2.3 Mechanical Specifications 2.4 External Features 2.5 Front Panel Installation C H A P T E R 3.1 Introduction 78-16033-01 C O N T E N T S xxii Cisco ONS 15216 EDFA2 Operations Guide...
  • Page 4 4.15 Recover Default Password SNMP MIB Installation and Configuration C H A P T E R 5.1 SNMP Overview 5.1.1 SNMP Components 5.1.2 ONS 15216 EDFA2 SNMP Elements 5.1.3 SNMP MIBs and Message Types Cisco ONS 15216 EDFA2 Operations Guide 3-14 4-10...
  • Page 5 6.2.4 srom cfg ip modify Command 6.2.5 pdm busmode display Command 78-16033-01 5-10 5-11 5-12 5-14 5-16 5-18 5-18 5-19 5-20 5-21 5-21 5-22 5-23 5-23 5-24 5-24 5-24 5-25 5-26 5-27 5-29 5-30 5-31 5-34 5-36 5-37 Cisco ONS 15216 EDFA2 Operations Guide Contents...
  • Page 6 6.6.13 snmp table display Command 6.6.14 snmp table get Command 6.6.15 snmp table list Command 6.6.16 snmp tree attribute list Command 6.7 User Commands 6.7.1 user entry create Command Cisco ONS 15216 EDFA2 Operations Guide 6-10 6-10 6-10 6-11 6-11...
  • Page 7 8.11 Log Off 8.12 Back Up System Configuration 8.13 Restore System Configuration 78-16033-01 6-26 6-27 6-28 6-29 6-29 6-30 6-31 6-31 6-31 6-32 8-10 8-11 8-11 8-11 8-12 Contents 6-27 6-28 6-30 6-30 6-32 6-32 Cisco ONS 15216 EDFA2 Operations Guide...
  • Page 8 F I N A L D R A F T - C I S C O C O N F I D E N T I A L TL1 Commands C H A P T E R 9.1 Introduction 9.2 Connection to the ONS 15216 EDFA2 9.3 Explanation of Command Parameters 9.3.1 Source Identifier (sid) and Target Identifier (tid) 9.3.2 Command Code Modifier (ccm) 9.3.3 Access Identifier (aid)
  • Page 9 10.2.7 LAN Port Activity LED Stays On 10.2.8 Lost Password 10.3 Status Information Needed by Cisco TAC 78-16033-01 9-41 9-43 9-44 9-46 9-47 9-48 9-50 9-51 9-51 9-52 9-54 9-55 9-56 9-57 9-59 9-60 9-60 9-61 9-62 9-63 9-64 Contents Cisco ONS 15216 EDFA2 Operations Guide...
  • Page 10 Chassis Power Connection Cisco ONS 15216 EDFA2 Temperature Requirement VCCI Compliance for Class B Equipment SELV-IEC 60950 DC Power Supply Warning Cisco ONS 15216 EDFA2 Power Circuit Overload Warning Product Disposal Warning Energy Hazard Unit Grounding Protection Warning DC Power Disconnection Warning...
  • Page 11 Cable Connection Sequence Warning A-42 Module Removal Warning A-43 DC Power SELV Requirement Warning A-44 Reinforced Insulation Warning A-45 Power Supply Voltage Warning A-46 DC Power Supply Connection Warning A-46 N D E X Cisco ONS 15216 EDFA2 Operations Guide 78-16033-01...
  • Page 12 Contents F I N A L D R A F T - C I S C O C O N F I D E N T I A L Cisco ONS 15216 EDFA2 Operations Guide 78-16033-01...
  • Page 13 ONS 15216 EDFA2 Front Panel Figure 5-1 SNMP Elements Figure 5-2 SNMP Agent and MIB Figure 8-1 ONS 15216 EDFA2 Front Panel 78-16033-01 3-10 3-10 3-11 3-14 F I G U R E S Cisco ONS 15216 EDFA2 Operations Guide xiii...
  • Page 14 Figures F I N A L D R A F T - C I S C O C O N F I D E N T I A L Cisco ONS 15216 EDFA2 Operations Guide 78-16033-01...
  • Page 15 Maximum Channel Power Table 2-3 ONS 15216 EDFA2 Electrical Specifications Table 2-4 ONS 15216 EDFA2 Mechanical Specifications Table 2-5 ONS 15216 EDFA2 Front Panel Features Table 3-1 Gain Range Table 3-2 Alarm Pinout and Definitions (RJ-45) Table 3-3 Equipment Checklist...
  • Page 16 Table 9-31 RTRV-ALM-DWDM Syntax Description Table 9-32 RTRV-ALM-ENV Syntax Description Table 9-33 RTRV-ALM-EQPT Syntax Description Table 9-34 RTRV-AO Syntax Description Table 9-35 RTRV-COND-ALL Syntax Description Cisco ONS 15216 EDFA2 Operations Guide 9-10 9-12 9-13 9-14 9-15 9-16 9-16 9-17 9-18...
  • Page 17 SET-TH-ENV Syntax Description Table 9-54 SET-TH-EQPT Syntax Description Table A-1 Regulatory Standards Compliance 78-16033-01 9-43 9-45 9-46 9-48 9-49 9-50 9-51 9-52 9-53 9-54 9-55 9-57 9-58 9-59 9-60 9-61 9-61 9-62 9-63 Cisco ONS 15216 EDFA2 Operations Guide Tables xvii...
  • Page 18 Tables F I N A L D R A F T - C I S C O C O N F I D E N T I A L Cisco ONS 15216 EDFA2 Operations Guide xviii 78-16033-01...
  • Page 19: Obtaining Documentation

    Obtaining Documentation Cisco provides several ways to obtain documentation, technical assistance, and other technical resources. These sections explain how to obtain technical information from Cisco Systems. Cisco.com You can access the most current Cisco documentation on the World Wide Web at this URL: http://www.cisco.com/univercd/home/home.htm...
  • Page 20: Documentation Feedback

    Nonregistered Cisco.com users can order documentation through a local account representative by • calling Cisco Systems Corporate Headquarters (California, U.S.A.) at 408 526-7208 or, elsewhere in North America, by calling 800 553-NETS (6387). Documentation Feedback You can submit comments electronically on Cisco.com. On the Cisco Documentation home page, click Feedback at the top of the page.
  • Page 21: Technical Assistance Center

    SMARTnet, SMARTnet Onsite, or Network Supported Accounts (NSA). When you call the center, please have available your service agreement number and your product serial number. 78-16033-01 Obtaining Technical Assistance Cisco ONS 15216 EDFA2 Operations Guide...
  • Page 22: Obtaining Additional Publications And Information

    Information about Cisco products, technologies, and network solutions is available from various online and printed sources. The Cisco Product Catalog describes the networking products offered by Cisco Systems as well as • ordering and customer support services. Access the Cisco Product Catalog at this URL: http://www.cisco.com/en/US/products/products_catalog_links_launch.html...
  • Page 23: Bandwidth On Demand

    (DWDM) links by hundreds of kilometers. With the ONS 15216 EDFA2, optical signals from a span in a DWDM network can be added or dropped without negatively affecting (degrading) other optical signals on the same span.
  • Page 24: Figure 1-2 Ons 15216 Edfa2 Block Diagram

    After a protection switch occurs, the number of wavelengths on each fiber changes. In the example, the number of clockwise wavelengths increases to three, while the number of counter-clockwise wavelengths decreases to one. 1.3 Key Features Figure 1-2 shows a block diagram of the ONS 15216 EDFA2. Figure 1-2 ONS 15216 EDFA2 Block Diagram Input Isolator...
  • Page 25: Figure 1-3 Gain Flattening Filter

    1.3.2 Gain Flattening Figure 1-3 illustrates the effect of the gain flattening filter in the ONS 15216 EDFA2. Fiber (a) in the figure shows a set of channels with equal powers being input to a cascaded network of amplifiers that produce vastly different power levels and optical signal-to-noise ratios (OSNR) at the output.
  • Page 26: Transient Suppression

    Whenever there is gain in an optical system, noise also occurs. The predominant source of noise in EDFAs is amplified spontaneous emission (ASE). The ONS 15216 EDFA2 has a low noise figure of less than 7 dB at –5 dBm input.
  • Page 27: Technical Specifications

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L Technical Specifications This chapter discusses the technical specifications for the Cisco ONS 15216 EDFA2. 2.1 Optical Specifications...
  • Page 28: Table 2-2 Maximum Channel Power

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L 2.1.1 Maximum Input Power The ONS 15216 EDFA2 operates at a gain setting between 13 and 22 dB. Each gain setting has a maximum input power. The maximum input power is defined as 17 dBm (the maximum output power) minus the gain setting.
  • Page 29: Table 2-3 Ons 15216 Edfa2 Electrical Specifications

    Max. Gain (dB) Number of Channels at Full Loading 18– 2.2 Electrical Specifications The ONS 15216 EDFA2 uses a power supply that meets the electrical specifications listed in Table 2-3 ONS 15216 EDFA2 Electrical Specifications Requirement Input voltage Maximum power consumption...
  • Page 30: Table 2-4 Ons 15216 Edfa2 Mechanical Specifications

    Humidity storage Connector types Mean time between failures (MTBF) 2.4 External Features The ONS 15216 EDFA2 has the following external features: • Front panel LEDs, graphics, and warning displays Brackets for rack mounting (including reversible ears that permit front, mid, •...
  • Page 31: Front Panel

    Figure 2-1 ONS 15216 EDFA2 Dimensions 2.5 Front Panel Figure 2-2 shows the ONS 15216 EDFA2 front panel in detail. The front panel provides an all-front access (fibers, power, alarm contact, and management interface) that complies with international standards. Figure 2-2...
  • Page 32: Table 2-5 Ons 15216 Edfa2 Front Panel Features

    Chassis ground lugs Cisco ONS 15216 EDFA2 Operations Guide Description Terminal strip for supplying power to the ONS 15216 EDFA2. Attach AWG 18 stranded power wires to appropriate terminals. Threaded grounding holes (#10-32) to ground the ONS 15216 EDFA2. RJ-45 connector used for alarm system connection. (See the Out Relay Interface (RJ-45)”...
  • Page 33: Standard Precautions

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L Installation 3.1 Introduction This chapter contains the installation procedures for the Cisco ONS 15216 EDFA2. The chapter is divided into the following sections: •...
  • Page 34: Rack Installation And Power Supply Connection Procedures

    OFF position. Follow these steps to install the ONS 15216 EDFA2 into the rack and correctly set up the power supply: Mount the ONS 15216 EDFA2 in the rack (19 inches or 23 inches reversible ears). Empty rack space is Step 1 not required above or below the ONS 15216 EDFA2.
  • Page 35: Sc/Upc Optical Ports

    (eye loupes, microscopes) within a distance of 100 mm may pose an eye hazard. In the event of a fiber cut or loss of connection and there is no input power, the ONS 15216 EDFA2 still Warning has –3.5 dBm of optical output power.
  • Page 36: Optical Amplification Operation Verification Procedure

    Note Unless overridden by the user, the gain per channel is by default set to 22 dB by the ONS 15216 EDFA2. Gain is fixed at 22 dB as long as total input power is less than or equal to –5 dBm. If your input power is higher than –5 dBm, see the...
  • Page 37: Communications

    LAN interface (RJ-45) • 3.5.1 Alarm Out Relay Interface (RJ-45) The ONS 15216 EDFA2 Alarm Out (RJ-45) port reports alarm status for the following: Loss or degradation of electrical power • Laser pump overheating or excessive pump current, output power, gain, and case temperature •...
  • Page 38: Alarm Leds

    Three of these LEDs, POWER, FAIL, and LOS, are located at the left side of the front panel of the ONS 15216 EDFA2. The two Ethernet LEDs are located at the top left and right sides of the Ethernet socket. When the module is powered on, an LED test is performed.
  • Page 39: Serial Interface (Eia/Tia-232) Communication

    3.5.2.3 LOS LED (Yellow) The loss of signal (LOS) LED is yellow. This LED functions as follows: • On: The optical input power to the ONS 15216 EDFA2 is below the loss of input threshold. (A LOS threshold decision occurs.) •...
  • Page 40: Figure 3-2 Hyperterminal Connect To Dialog Box

    Parity—None • Stop bits—1 • Flow control—None • Click OK when done. Cisco ONS 15216 EDFA2 Operations Guide (Figure 3-2), click Direct to Com1 in the Connect using field. Click OK. Chapter 3 Installation Figure 3-3 on page 3-9. The...
  • Page 41 Optical Amplifier Properties Dialog Box (Connect To Tab) Ensure that Direct to Com1 is selected in the Connect using field. Step 9 Click Settings (Figure 3-5 on page Step 10 78-16033-01 3-10) and click ASCII Setup. Cisco ONS 15216 EDFA2 Operations Guide Communications Figure 3-4.
  • Page 42: Figure

    Click OK to return to the main HyperTerminal window. Step 12 The ONS 15216 EDFA2 login screen appears. The appearance depends on the shell the ONS 15216 EDFA2 is set to (TL1 is the default shell). See Using HyperTerminal” section on page 4-1 (EIA/TIA-232) Port Using HyperTerminal”...
  • Page 43: Serial Interface Remote Communication Via Modem

    Remote Site and Local Site. The Remote Site section lists components needed at the site that contains the ONS 15216 EDFA2 and the Local Site section lists components needed at the site where the user is located.
  • Page 44: Table 3-5 Modem Dip Switch Setting

    • 1 stop bit, and no flow control Table 3-6 on page 3-13 settings survive power supply interruptions. Use these settings to configure each modem. Cisco ONS 15216 EDFA2 Operations Guide 3-12 Notes For connection between the modem and PSTN dial-up telephone line.
  • Page 45: Table 3-6 Modem Settings

    Modem controls Data Set Ready (DSR) Prohibits remote digital loopback Fix lowest connect speed to 14,400 bps Break handling; destructive/expedited Store configuration 0 Auto-answer on first ring Disable escape to command mode Cisco ONS 15216 EDFA2 Operations Guide Communications 3-13...
  • Page 46: Lan Interface (Ethernet)

    3.5.4.6 PC Connection via Modem The ONS 15216 EDFA2 and modem are connected through the RS-232 (EIA/TIA-232) port using a DB-9 connector. The modem, PC, and ONS 15216 EDFA2 should be physically set up as displayed in Figure 3-8. Use...
  • Page 47: Log In Via Rs-232 (Eia/Tia-232) Port Using Hyperterminal

    Use the following procedure to configure the module to accept SNMP, CLI, and TL1 commands via its RJ-45 LAN port: The ONS 15216 EDFA2 IP address is factory set at 0.0.0.0. The IP address must be set before the Step 1 ONS 15216 EDFA2 can be accessed via the Ethernet port.
  • Page 48 Chapter 3 Installation Communications F I N A L D R A F T - C I S C O C O N F I D E N T I A L Cisco ONS 15216 EDFA2 Operations Guide 3-16 78-16033-01...
  • Page 49 The following sections describe these steps in detail. 4.1 Log In via RS-232 (EIA/TIA-232) Port Using HyperTerminal Logging in through the RS-232 (EIA/TIA-232) port is required to set the ONS 15216 EDFA2 IP address before there can be access via the LAN port. (See on page 4-3.)
  • Page 50 If you see the login window shown in Step 3 By default the ONS 15216 EDFA2 is in TL1 shell, so this step may be required to proceed in ASH shell. When in TL1 shell, the screen opens to a simple prompt (...
  • Page 51: Set Ip Address

    <ONS 15216 EDFA2 IP address> 8023 Specifying port 8023 ensures login through the ASH shell. If no port is specified, the ONS 15216 EDFA2 responds in the shell that the ONS 15216 EDFA2 is set to. (TL1 is the default shell.) 78-16033-01 Example 4-3) and press Enter.
  • Page 52: Set Date And Time

    4.5 Set Power Bus Mode (Simplex or Duplex) The ONS 15216 EDFA2 allows users to set a simplex (one power source–Bus A) or duplex (redundant power source–Bus A and Bus B) Power Bus mode. Use the snmp attribute set local cerent15216EdfaPowerBusMode command to set the desired Power Bus mode.
  • Page 53: Set Gain

    For more information, refer to 4.7 Set Gain To ensure that the ONS 15216 EDFA2 output signal is received by the transceiver in the network element, it is important that the gain is set correctly.
  • Page 54 To set the alarm thresholds, use the snmp row set local cerent15216EdfaCfgGroup command. After this command is entered, the user is prompted to modify each attribute, row by row, until all attributes are set. Alarm threshold attributes are described in Cisco ONS 15216 EDFA2 Operations Guide Fiber Status...
  • Page 55: Table 4-1 Alarm Threshold Attribute Definitions

    Constant Output Power and Idle modes. the optical input signal of the ONS 15216 EDFA2 drops below a level that impacts proper operation of optical network. Set this attribute at a value that...
  • Page 56 1 dB, the power alarm hysteresis is 100. the case temperature of the ONS 15216 EDFA2 drops below a level that impacts proper operation of the optical network. The minimum case temperature should be set at a value that...
  • Page 57 Set Alarm Thresholds Description the case temperature of the ONS 15216 EDFA2 is at a level that may impact proper operation of the optical network. Set the maximum case temperature at a value that is appropriate for intended application and within product specifications.
  • Page 58: Set Password

    4.9 Set Password To restrict access to the ONS 15216 EDFA2, use the user passwd set command to change the default user password. The password must be a string of up to 10 characters, where at least 2 are non-alphabetic characters and at least 1 is a special character.
  • Page 59: Add Users

    Enter. 4.10 Add Users Use the user entry create command to add new users to the ONS 15216 EDFA2. The syntax is to enter the command followed by the user name and then the access level (read, read_write, read_write_admin)
  • Page 60: Log Off

    – cerent15216EdfaBootFileName – 4.12 Log Off At the end of a session, the user must log off of the ONS 15216 EDFA2. To log off, use the logoff command. This is shown in Example 4-12 Logging Off ash:hostname:ONS15216 EDFA2> logoff 4.13 Back Up System Configuration...
  • Page 61: Restore System Configuration

    ONS 15216 EDFA2 memory and FFS. Before the restore begins, a cyclic redundancy code (CRC) check is performed to ensure data integrity. If desired, use FTP to copy a system configuration file from a remote server to the ONS 15216 EDFA2 Step 1 FFS.
  • Page 62: Recover Default Password

    If the root password for CISCO15 is lost, there is a procedure to reset it to regain full administrative control of the ONS 15216 EDFA2. The user must be connected to the ONS 15216 EDFA2 by serial communication, perform a hard power reset, and then performs a series of commands within 60 seconds of rebooting, according to the following procedure.
  • Page 63: Chapter 5 Snmp Mib Installation And Configuration

    This chapter explains how to read and understand SNMP MIB as it relates to the Cisco ONS 15216 EDFA2. This chapter is a reference of all ONS 15216 EDFA2 SNMP commands that are used in a network management system (NMS). For provisioning the ONS 15216 EDFA2, see “Provisioning Using ASH and...
  • Page 64: Ons 15216 Edfa2 Snmp Elements

    To generate reports, an agent must be notified of internal events. Cisco provides both an SNMP agent (installed on the ONS 15216 EDFA2) and SNMP MIB to monitor the ONS 15216 EDFA2. The SNMP agent software and MIB are pre-installed on each module.
  • Page 65: Snmp Mibs And Message Types

    SNMP agent. 5.1.2.3 SNMP Manager The ONS 15216 EDFA2 comes with a pre-installed SNMP manager accessible via the CLI. This SNMP manager can be accessed and used to communicate with the SNMP agent that is also pre-installed on each ONS 15216 EDFA2.
  • Page 66: Command Syntax Using The Snmp Agent

    5.1.4 Command Syntax Using the SNMP Agent Although Cisco has its own separate SNMP manager (Cisco Transport Manager [CTM]), management of the ONS 15216 EDFA2 is also possible using the built-in SNMP manager via the command line in the ASH shell, as described in described in this manual are based on using the built-in ONS 15216 EDFA2 SNMP manager through the ASH shell CLI.
  • Page 67: Enabling Snmp Remote Management Community Strings

    SNMP communities are groupings of workstations and servers (or gateways) that can manage the ONS 15216 EDFA2. NMSs use SNMP communities to enforce security. SNMP enforces security through password-like community strings. Access to the SNMP agent and the ONS 15216 EDFA2 can be limited by both IP address and community string.
  • Page 68: Creating A View

    = cerent15216EdfaViewMask = cerent15216EdfaViewType = cerent15216EdfaViewStatus = Access to the ONS 15216 EDFA2 can be restricted by IP address or community string using this command. Table 5-3 on page 5-7 Cisco ONS 15216 EDFA2 Operations Guide cerent15216EdfaViewEntry Set Command { sample };...
  • Page 69: Creating A Community Entry

    SNMP communities are groupings of workstations and servers (or gateways) that can manage the ONS 15216 EDFA2. NMSs use SNMP communities to enforce security. Because access to the SNMP agent is controlled by a community entry, every SNMP agent must be configured to recognize one or more community names, and to provide the appropriate level of access to managers according to the community name.
  • Page 70: Table 5-4 Creating A Community Entry

    Cisco ONS 15216 EDFA2 Operations Guide Chapter 5 SNMP MIB Installation and Configuration Description Community Index: An index that uniquely identifies a particular SNMP community. This community index is part of the command. In Example 5-4 on page Community Name: The community string.
  • Page 71: Table 5-5 Snmp Operation Decimal Values

    247 is the sum for all SNMP operations with the exception of the Set operation. This sum is the default public community. 78-16033-01 cerent15216EdfaCommunityEntry Display Command "private"; 255; 0.0.0.0; 255.255.255.255; active; Enabling SNMP Remote Management Community Strings Decimal Values Cisco ONS 15216 EDFA2 Operations Guide...
  • Page 72: Setup For Ctm Access

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L 5.3 Setup for CTM Access Use the following procedure to configure a new ONS 15216 EDFA2 for Cisco Transport Manager (CTM) access: Log into the serial port.
  • Page 73: Tables And Groups

    EDFA2> logoff 5.4 Tables and Groups The cerent15216Edfa.mib contains several key tables that are used to review and provision the ONS 15216 EDFA2. The following tables are listed and described in the following sections: CfgGroup Table, page 5-12 •...
  • Page 74: Cfggroup Table

    Hysteresis Cisco ONS 15216 EDFA2 Operations Guide 5-12 Chapter 5 Table 5-6 “Set Alarm Thresholds” section on page Maximum Syntax Access Description True Value Read-only Indicates whether the current configuration has been saved.
  • Page 75 570 (-57 VDC), the alarm will not raise until the voltage goes above -58 VDC and will not clear until the voltage goes below -56 VDC. Cisco ONS 15216 EDFA2 Operations Guide Tables and Groups 5-13...
  • Page 76: Pumpcfgentry Table

    The associated table command displays a settings summary or allows you to set pumps. See for variable definitions. The factory default pump control mode for the ONS 15216 EDFA2 is Constant Gain Temperature Compensated. Cisco recommends that users contact the Cisco TAC prior to changing this mode of operation.
  • Page 77 Step 4 Example 5-6 shows how to set the ONS 15216 EDFA2 to Constant Pump Current mode and then set it back to Constant Gain Temperature Compensated mode. (Setting pump 1 or 2 to Constant Gain Temperature Compensated mode sets both pumps to that mode.) Example 5-6 ash:hostname:ONS15216 EDFA2>...
  • Page 78: Overallstatusgroup Table

    5.4.3 OverallStatusGroup Table The cerent15216EdfaOverallStatusGroup table allows users to display the input and output of the ONS 15216 EDFA2 amplifier. table variables. Cisco ONS 15216 EDFA2 Operations Guide 5-16 for pump 2. for pump 2. Changing Value for Constant Pump Current Mode...
  • Page 79 Read-only Integer (–99999 to Read-only 99999) Integer (0 to 230) Read-only Integer (0 to 110) Read-only Cisco ONS 15216 EDFA2 Operations Guide Tables and Groups Description EDFA input power (*10 microW) EDFA input power (*100 dBm) EDFA output power (*100...
  • Page 80: Overallcontrol Table

    Table 5-10 cerent15216EdfaPumpStatusEntry Variable Descriptions Variable cerent15216EdfaPumpStatusPumpNum cerent15216EdfaPumpStatusLaserChipTemp cerent15216EdfaPumpStatusLaserChipTemp Setpoint cerent15216EdfaPumpStatusLaserTECCurre cerent15216EdfaPumpStatusLaserPower cerent15216EdfaPumpStatusLaserCurrent cerent15216EdfaPumpStatusAmbientTemp Cisco ONS 15216 EDFA2 Operations Guide 5-18 Table 5-9 describes cerent15216EdfaOverallControl variables. Maximum Syntax Access Integer (130 to Read-write 220) Integer (10 to...
  • Page 81: Alarmentry Table

    The cerent15216EdfaPumpStatusGain variable should not be confused with the cerent15216EdfaConstGainOverallGain variable that is used to set the gain of the ONS 15216 EDFA2. The cerent15216EdfaPumpStatusGain is the value of the gain of the amplification module only, it does not take into account the VOA (variable optical attenuator) attenuation.
  • Page 82: Opgroup Table

    Table 5-12 cerent15216EdfaOpGroup Variable Descriptions Variable cerent15216EdfaOpStatus cerent15216EdfaOpResult cerent15216EdfaOpRequest cerent15216EdfaOpSaveCo nfig cerent15216EdfaOpCutover cerent15216EdfaActio cerent15216EdfaOpLoad Cisco ONS 15216 EDFA2 Operations Guide 5-20 Chapter 5 Maximum Syntax Access cerent15216EdfaControl Read-write If the alarm is cerent15216EdfaDateAndTime Read-only...
  • Page 83: Versiongroup Table

    5.5 Setting Up Traps Traps are asynchronous notifications sent from the ONS 15216 EDFA2 to a predetermined location (IP address, subnet mask, etc.). A community entry must be created prior to remotely setting up traps using either Telnet or a terminal server.
  • Page 84: Display Trap Command

    EDFA2> snmp table display local cerent15216EdfaCommTrapEntry CLASS CERENT-15216-EDFA-MIB.cerent15216EdfaCommTrapEntry ::= cerent15216EdfaCommTrapIndex = cerent15216EdfaCommTrapCommunity = cerent15216EdfaCommTrapDestIPAddress = cerent15216EdfaCommTrapDestUDPPort = cerent15216EdfaCommTrapViewIndex = cerent15216EdfaCommTrapVersion = cerent15216EdfaCommTrapStatus = Cisco ONS 15216 EDFA2 Operations Guide 5-22 MIB Items cerent15216EdfaOpSaveConfig cerent15216EdfaOpCutover cerent15216EdfaOpLoad cerent15216EdfaOpReset cerent15216EdfaAlarmID cerent15216EdfaAlarmPrioriy cerent15216EdfaAlarmDateAndTime...
  • Page 85: Set Trap Command

    Enables or disables SNMP traps depending on whether the parameter control is “enabled” or “disabled”. 78-16033-01 displays the prompts that appear after entering the command. cerent15216EdfaCommTrapEntry Set Command Setting Up Traps Cisco ONS 15216 EDFA2 Operations Guide 5-23...
  • Page 86: Get Agent Trap Enable

    Syntax Description snmp table display local cerent15216EdfaSromIpMgmtGroup Displays the ONS 15216 EDFA2 IP address. The following SNMP command displays the ONS 15216 EDFA2’s IP address and other networking information: • snmp row display local cerent15216EdfaSromIpMgmtGroup command Example 5-10 cerent15216EdfaSromIpMgmtGroup Display Command ash:hostname:ONS15216 EDFA2>...
  • Page 87: Date And Time

    • snmp row display local cerent15216EdfaRtcDateAndTime command The following SNMP command sets the date and time for the ONS 15216 EDFA2 and other time data: snmp attribute set local cerent15216EdfaRtcDateAndTimeLocalString command • When setting the local time of day, set the time zone first, set the DST offset second, and set the local time last.
  • Page 88: Power Gain

    Syntax Description snmp attribute get local cerentEdfa15216EdfaConstGainOverallGain # Displays the overall power gain when the ONS 15216 EDFA2 is in Constant Gain Temperature Compensated mode. The following commands access overall power gain when in the Constant Gain Temperature...
  • Page 89: Case Temperature

    This command displays minimum case temperature alarm threshold. 78-16033-01 (Example 5-13). 260; 260; 8503; 17010; 2272; 250; -600; 5000; 1700; 220; for information about all of the parameters in the Cisco ONS 15216 EDFA2 Operations Guide Retrieving Information 5-27...
  • Page 90 Displays maximum case temperature alarm hysteresis. The cerent15216EdfaCtmpMaxHysteresis attribute in the cerent15216EdfaCfgGroup display command shows the maximum case hysteresis temperature alarm threshold Table 5-6 on page 5-12 Cisco ONS 15216 EDFA2 Operations Guide 5-28 Chapter 5 Example 5-14.
  • Page 91: Power Bus

    Displays the maximum allowable power bus DC voltage (multiplied by –10V). The following command displays power bus voltage and other data: • snmp row display local cerent15216EdfaCfgGroup command 78-16033-01 Retrieving Information Example 5-14 on page 5-28. For information Table 5-6 on page 5-12. Cisco ONS 15216 EDFA2 Operations Guide 5-29...
  • Page 92: Input Power (Signal)

    Syntax Description snmp attribute get local cerent15216EdfaInPoweruW Displays input power value in microwatts. The following command displays the ONS 15216 EDFA2 input power value and other status information: snmp row display local cerent15216EdfaOverallStatusGroup command •...
  • Page 93: Output Power

    Syntax Description snmp attribute get local cerent15216EdfaOutPowermW 78-16033-01 (Example 5-14 on page 5-28). (Example 5-14 on page 5-28). For information about all of the Table 5-6 on page Cisco ONS 15216 EDFA2 Operations Guide Retrieving Information Table 5-6 on 5-12. 5-31...
  • Page 94 Displays output power value in milliwatts. The snmp row display local cerent15216EdfaOverallStatusGroup command displays the ONS 15216 EDFA2 output power value and additional pump status. For information about all of the parameters in the cerent15216EdfaOverallStatusGroup table, refer to 5.6.7.1.2 OutPowerdBm...
  • Page 95 To set the loss of output power alarm deviation when the ONS 15216 EDFA2 is configured for operation in Constant Output Power or Constant Pump Power mode, type snmp attribute set local...
  • Page 96: Database Backup And Restore

    Changes must be saved before terminating the session. See the 5.6.8 Database Backup and Restore The configuration information for the ONS 15216 EDFA2 can be saved in a file for later use or to configure other ONS 15216 EDFA2 units. This file contains manufacturing information about the unit...
  • Page 97 Step 6 5.6.8.2 Database Restore Procedure The configuration information for the ONS 15216 EDFA2 can be restored form a file. During this process, all configuration information (such as alarm thresholds and pump mode) and the user database from the file are replaced in the ONS 15216 EDFA2 memory and FFS.
  • Page 98: Alarm Entry

    Verify that cerent15216EdfaOpResult is 0. Save the changes by setting cerentEdfa15216OpSaveConfig = 2. Step 2 Reboot the ONS 15216 EDFA2 by setting cerentEdfa15216OpReset = 2. Step 3 After the processor reboots, user names and passwords from the new user database must be used for access.
  • Page 99: Summary Of Snmp Alarms

    5-19. 5.7 Summary of SNMP Alarms Table 5-17 summarizes the ONS 15216 EDFA2 SNMP alarms. Table 5-17 SNMP Alarms Alarm Index 1. A single power bus alarm is Minor. If the power system is in duplex mode and an alarm is raised on both power buses, the second alarm is Critical.
  • Page 100 Summary of SNMP Alarms F I N A L D R A F T - C I S C O C O N F I D E N T I A L Cisco ONS 15216 EDFA2 Operations Guide 5-38 78-16033-01...
  • Page 101: Chapter 6 Ash Commands

    SNMP instructions. This chapter is a reference of ASH commands that are used in advanced setup and troubleshooting. For provisioning the Cisco ONS 15216 EDFA2 using ASH commands, see All commands discussed in this chapter are available to the default CISCO15 user and any other user with read_write_admin (RWA) access privileges.
  • Page 102 Enables access to manufacturer commands. manufacturer restore defaults all Cisco ONS 15216 EDFA2 Operations Guide Description Formats flash file system. Displays current flash file system status. Copies TFTP file to flash file system.
  • Page 103 Command, page Gets an attribute. snmp attribute get Command, page Lists an attribute. snmp attribute list Command, page get an attribute set an attribute Cisco ONS 15216 EDFA2 Operations Guide User Access Levels 6-12. 6-31. 6-13. 6-13. 6-15.
  • Page 104 Cisco ONS 15216 EDFA2 Operations Guide Description Sets an attribute. snmp attribute set Command, page Gets the IP address from host name. Gets the host name from IP address.
  • Page 105 Displays the user names and information. user file display and user name display Commands, page 6-27. Displays user inactivity times. user inactivity modify and user inactivity display Commands, page 6-28. Cisco ONS 15216 EDFA2 Operations Guide User Access Levels 6-6. 6-7. 6-7. 6-29. 6-26. 6-27.
  • Page 106: Configuration Commands

    Sets another user’s password. voa power input display 6.2 Configuration Commands The following commands are useful in configuring the ONS 15216 EDFA2: srom cfg boot display Command, page 6-6 • srom cfg boot modify Command, page 6-7 •...
  • Page 107: Srom Cfg Boot Modify Command

    Displays the serial ROM IP contents. The ROM IP contents are shown, including IP address, subnet mask, default router address, and hostname. See 78-16033-01 srom cfg boot display Command Example srom cfg boot modify Command Example Configuration Commands 6-2. 6-3. Cisco ONS 15216 EDFA2 Operations Guide...
  • Page 108: Srom Cfg Ip Modify Command

    6.2.5 pdm busmode display Command Command pdm busmode display Syntax Description pdm busmode display Displays power bus mode (simplex or duplex). Cisco ONS 15216 EDFA2 Operations Guide srom cfg ip display Command srom cfg ip modify Command Chapter 6 ASH Commands 78-16033-01...
  • Page 109: Pdm Busmode Modify Command

    BUS Threshold High 6.2.9 gain gain display Command Command gain gain display 78-16033-01 pdm cfg threshold bus display Command = 40000(mV) = 57000(mV) pdm cfg threshold bus modify Command = 40000(mV) = 57000(mV) Configuration Commands Cisco ONS 15216 EDFA2 Operations Guide...
  • Page 110: Gain Gain Modify Command

    Syntax Description voa power input display Displays variable optical attenuator (VOA) power input. 6.3 Administrative Commands The following commands are useful in administering the ONS 15216 EDFA2: clear Command, page 6-11 • exit Command, page 6-11 •...
  • Page 111: Clear Command

    Clears content from the terminal window. An empty screen with a cursor appears. 6.3.2 exit Command Command exit Syntax Description exit Ends the session with the ONS 15216 EDFA2. 6.3.3 help Command Command help Syntax Description help Displays a list of all CLI commands for current user security level.
  • Page 112: Login And Logoff Commands

    Syntax Description login or logoff Used to access and exit communication with the ONS 15216 EDFA2. Logging into the module requires both a user name and a password. Only use these commands if you have stopped the booting process or are displaying the format for logging into the module.
  • Page 113: Shell Lines Set Command

    Example 6-11 shell status display Command ash:hostname:ONS15216 EDFA2> shell status display Shell Lines: 22 Shell Rows : 80 More : On 6.4.4 shell type modify Command Command shell type modify 78-16033-01 Shell Commands Example 6-11. Cisco ONS 15216 EDFA2 Operations Guide 6-13...
  • Page 114: Flash File System Commands

    Syntax Description shell type modify {tl1 | ash} Sets the shell type to TL1 or ASH for the ONS 15216 EDFA2’s RS-232 (EIA/TIA-232) port (accessed via HyperTerminal) and the default TCP/IP port on the ONS 15216 EDFA2’s LAN port (accessed via Telnet).
  • Page 115: Snmp Commands

    The SNMP commands are useful in working with the SNMP protocol to provision and configure the ONS 15216 EDFA2. When issuing these SNMP commands, the command syntax requires that the command must be followed by either the ONS 15216 EDFA2 IP address or the word “local”. SNMP commands are listed as follows: snmp attribute get Command, page 6-15 •...
  • Page 116: Snmp Attribute List Command

    EDFA2> snmp attribute list local cerent15216EdfaAlarmID cerent15216EdfaAlarmID.1 = cerent15216EdfaAlarmID.2 = cerent15216EdfaAlarmID.3 = cerent15216EdfaAlarmID.4 = cerent15216EdfaAlarmID.5 = cerent15216EdfaAlarmID.6 = cerent15216EdfaAlarmID.7 = cerent15216EdfaAlarmID.8 = cerent15216EdfaAlarmID.9 = cerent15216EdfaAlarmID.10 = Cisco ONS 15216 EDFA2 Operations Guide 6-16 Example 6-15. lcrnt1; lcrnt2; ltmp1; ltmp2; lpout; lpin; gain;...
  • Page 117: Snmp Attribute Set Command

    Command snmp mib display Syntax Description snmp mib display {IP_address | local} -all Displays all writable MIB attributes (or all accessible attributes if the -all option is used). 78-16033-01 Example 6-16. Cisco ONS 15216 EDFA2 Operations Guide SNMP Commands 6-17...
  • Page 118: Snmp Mib Get Command

    EDFA2> snmp mib list local sysDescr.0 = Addr 00059a383d10"; sysObjectID.0 = sysUpTime.0 = sysContact.0 = sysName.0 = sysLocation.0 = sysServices.0 = Cisco ONS 15216 EDFA2 Operations Guide 6-18 Example "mntuboot v0.0.0 ONS15216 EDFA2 v1.3.0, MAC Addr 0010b4000525" cerent15216EdfaNode 24703705 "" "sysname" ""...
  • Page 119: Snmp Row Display Command

    { snmpBasicCompliance }; { rs232Compliance }; ""; ""; 355925; 355925; 300; 302; 350; "Intra-machine interface"; "Ethernet Interface"; "RS232 Interface"; softwareLoopback; ethernetCsmacd; rs232; 1500; 10000000; 19171; true; 1000; 200; 100; -2400; 100; SNMP Commands Example 6-19. Cisco ONS 15216 EDFA2 Operations Guide 6-19...
  • Page 120: Snmp Row Get Command

    Sets data within a row. Use the snmp row display command first to view the contents of data within a row. See Example Example 6-21 snmp row set Command ash:hostname:ONS15216 EDFA2> snmp row set local cerent15216EdfaAlarmEntry 1 cerent15216EdfaAlarmEnableStatus disabled Cisco ONS 15216 EDFA2 Operations Guide 6-20 "CLEI"; duplex; 480; 570;...
  • Page 121: Snmp Subtree Display Command

    Example 6-23 snmp subtree get Command ash:hostname:ONS15216 EDFA2> snmp subtree get local sysDescr index sysORIndex attributes sysORID 78-16033-01 Example "public"; 247; 0.0.0.0; 255.255.255.255; active; "private"; 255; 0.0.0.0; 255.255.255.255; active; Example 6-23. snmpBasicCompliance Cisco ONS 15216 EDFA2 Operations Guide SNMP Commands 6-22. 6-21...
  • Page 122: Snmp Subtree List Command

    EDFA2> snmp subtree list local internet sysDescr.0 = Cisco ONS 15216 EDFA2 Operations Guide 6-22 "" 391985 rs232Compliance "" 391990 "Intra-machine interface" softwareLoopback "hostname v3.0.0 ONS15216 EDFA2 v2.3.0, Serial No DIT0533000P, MAC...
  • Page 123: Snmp Table Display Command

    Syntax Description snmp table display {IP_address | local} Displays table data for the ONS 15216 EDFA2. table. After typing the command without a table and pressing the Tab key, a list of tables appears. Type the command with a table name to display the table and its data. Data displayed using this command are per rows.
  • Page 124: Snmp Table Get Command

    Example 6-27 snmp table list Command ash:hostname:ONS15216 EDFA2> snmp table list local udp udpInDatagrams.0 = udpNoPorts.0 = udpInErrors.0 = udpOutDatagrams.0 = udpLocalAddress.172.22.82.19.161 = udpLocalPort.172.22.82.19.161 = Cisco ONS 15216 EDFA2 Operations Guide 6-24 ""; 120; Example 6-26. "hostname, Hardware Rev A1, ONS15216 EDFA2, cerent15216EdfaNode 1330310 "username"...
  • Page 125: Snmp Tree Attribute List Command

    Commands, page 6-28 • user passwd set Command, page 6-28 • user active list Command, page 6-29 • user active message send Command, page 6-29 • 78-16033-01 User Commands Example 6-28. Cisco ONS 15216 EDFA2 Operations Guide 6-25...
  • Page 126: User Entry Create Command

    New Password = ****** Confirm New Password = ****** Cisco ONS 15216 EDFA2 Operations Guide 6-26 for the command privileges of each user level. The password must be an ASCII Example 6-30. The -user_mode parameter changes the access level (read, Example (string[0..10])
  • Page 127: User Entry Delete Command

    See Example 6-33 user file display Command ash:hostname:ONS15216 EDFA2> user file display User Mode CISCO15 read_write_admin 15 janedoe read_write jdoe read_write johndoe read 78-16033-01 Example 6-32. Inactivity User Commands Example 6-33. Cisco ONS 15216 EDFA2 Operations Guide Table 6-1 6-27...
  • Page 128: User Inactivity Modify And User Inactivity Display Commands

    6.7.6 user passwd set Command To restrict access to the ONS 15216 EDFA2, use the user passwd set command to change the default user password. displays the user passwd set username command for changing another user’s password. The password must be an ASCII string of up to 10 characters, where at least 2 are non-alphabetic characters with at least one special character.
  • Page 129: User Active List Command

    EDFA2> user active message send Parameters message ash:hostname:ONS15216 EDFA2> user active message send "hello world" *** Broadcast Message: *** hello world 78-16033-01 Example 6-38. Example (string[0..32]) message to send Cisco ONS 15216 EDFA2 Operations Guide User Commands 6-39. 6-29...
  • Page 130: Manufacturing Information Access Commands

    Displays information about autonomous messages (SNMP traps) going to destination manager’s location (IP address). Example 6-41 snmp table display local cerent15216EdfaCommTrapEntry Command ash:hostname:ONS15216 EDFA2> snmp table display local cerent15216EdfaCommTrapEntry CLASS CERENT-15216-EDFA-MIB.cerent15216EdfaCommTrapEntry ::= Cisco ONS 15216 EDFA2 Operations Guide 6-30 Example 6-40. "ONS15216 EDFA2";...
  • Page 131: Restore Commands

    Syntax Description backup system filename Creates a backup file on the FFS with the configuration information of the ONS 15216 EDFA2. This file contains manufacturing information about the unit that is being backed up (such as part number and serial number), setup information for the unit (such as IP address and host name), all configuration information (such as alarm thresholds and pump mode), and the user database.
  • Page 132: Manufacturer Mode

    Syntax Description manufacturer restore defaults all Restores the manufacturing factory settings to the ONS 15216 EDFA2. The files on the flash file system (FFS), the date and time, and the values of manufacturing calibration are not affected. This command must be followed by the processor reset command to take effect.
  • Page 133: Chapter 7 Ftp Command Line

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L FTP Command Line This chapter discusses the Cisco ONS 15216 EDFA2 FTP command line and explains how to get and send image and configuration files between an FTP server and the ONS 15216 EDFA2.
  • Page 134: Example Of Ftp To A Remote Server

    The FTP session is terminated and the following response should be displayed: Ftp session terminated. The ONS 15216 EDFA2 then returns to the hostname prompt. At the hostname prompt, check that the file was transferred and is complete using the following...
  • Page 135: Ftp Commands

    The FTP session is terminated and the following response should be displayed: Ftp session terminated. The ONS 15216 EDFA2 then returns to the hostname prompt. On the remote server, check that the file is present and complete. Step 8 7.2 FTP Commands...
  • Page 136: Ftp Commands

    FTP Command Line FTP Commands F I N A L D R A F T - C I S C O C O N F I D E N T I A L Cisco ONS 15216 EDFA2 Operations Guide 78-16033-01...
  • Page 137 The following sections describe these steps in detail. 8.1 Log In via RS-232 (EIA/TIA-232) Port Using HyperTerminal Logging in through the RS-232 (EIA/TIA-232) port is required to set the ONS 15216 EDFA2 IP address before there can be access via the LAN port (see on page 8-3).
  • Page 138: Chapter 8 Provisioning Using Tl1

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L If the ONS 15216 EDFA2 has been set to ASH shell, this step may is be required to proceed in TL1 shell.
  • Page 139: Set Ip Address

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L 8.2 Set IP Address Before connecting the ONS 15216 EDFA2 to a LAN, it is mandatory to set the ONS 15216 EDFA2 IP address through a local serial communication interface using the RS-232 (EIA/TIA-232) port on the front of the module.
  • Page 140: Set Date And Time

    8.5 Set Power Bus Mode (Simplex or Duplex) The ONS 15216 EDFA2 allows users to set a simplex (one power source–Bus A) or duplex (redundant power source–Bus A and Bus B) Power Bus mode. The default mode is duplex. Use the ED-ENV...
  • Page 141: Set Gain

    For more information, refer to 8.7 Set Gain To ensure that the ONS 15216 EDFA2 output signal is received by the transceiver in the network element, it is important that the gain is set correctly.
  • Page 142: Set Alarm Thresholds

    Displaying the Alarm Thresholds Using TL1 sidtidname:ONS15216 EDFA2> RTRV-TH-DWDM::ALL:124; sidtidname 2002-07-11 11:15:19 124 COMPLD "1,DWDM:LOSTH,,,-3000" "1,DWDM:LOSHYST,,,5" "1,DWDM:LPOUTDEV,,,1000" "1,DWDM:LPOUTHYST,,,5" "1,DWDM:LPOUTSETPT,,,0" sidtidname:ONS15216 EDFA2> RTRV-TH-EQPT::ALL:125; Cisco ONS 15216 EDFA2 Operations Guide Fiber Status output LEDs port POWER FAIL RS-232 CISCO ONS 15216 Fiber...
  • Page 143 Integer Read-write Alarm notifies operations personnel if (input power) (–3100 to threshold –1500) Cisco ONS 15216 EDFA2 Operations Guide Set Alarm Thresholds 9-63). Alarm threshold Description the optical input signal of the ONS 15216 EDFA2 drops below a level that impacts proper operation of optical network.
  • Page 144: Table 8-1 Alarm Threshold Attribute Definitions

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L Table 8-1 Alarm Threshold Attribute Definitions (continued) Attribute LOSHYST LPOUTDEV LPOUTHYST LPOUTSETPT Cisco ONS 15216 EDFA2 Operations Guide Variable Maximum Definition Syntax Access Loss of signal Integer...
  • Page 145 Cisco ONS 15216 EDFA2 Operations Guide Set Alarm Thresholds Description the case temperature of the ONS 15216 EDFA2 is at a level that may impact proper operation of the optical network. Set the maximum case temperature at a value that is appropriate for intended application and within product specifications.
  • Page 146: Set Password

    Alarm Threshold Attribute Definitions (continued) Attribute MINCTMPHYST 8.9 Set Password To restrict access to the ONS 15216 EDFA2, use the ED-PID command (see page 9-20) to change the default user password according to the following syntax: ED-PID:[<tid>]:<uid>:<ctag>::<oldpid>,<newpid>; Note that the password must be a string of up to 10 characters, where at least 2 are non-alphabetic characters and at least 1 is a special character.
  • Page 147: Add Users

    Example 8-10 Adding a New User Using TL1 sidtidname:ONS15216 EDFA2> ENT-USER-SECU::jsmith:140::jspasswd,,RW; 8.11 Log Off At the end of a session, the user must log off of the ONS 15216 EDFA2. To log off, use the CANC-USER command (see CANC-USER:[<tid>]:<uid>:<ctag>; Example Example 8-11 Logging Off Using TL1 sidtidname:ONS15216 EDFA2>...
  • Page 148: Restore System Configuration

    8.13 Restore System Configuration The configuration information for the ONS 15216 EDFA2 can be restored form a file. During this process, all configuration information (such as alarm thresholds and pump mode) and the user database from the file are replaced in the ONS 15216 EDFA2 memory and FFS.
  • Page 149: Chapter 9 Tl1 Commands

    The source identifier (sid) or target identifier (tid) parameters uniquely identify an ONS 15216 EDFA2. For the ONS 15216 EDFA2, sid and tid are the same. While the TL1 shell uses the sid/tid name in its command line prompt, the ASH shell uses the host name. The sid/tid name is the same as the sysName in the SNMP MIBs and is displayed in the upper-right of the login screen of the ASH shell.
  • Page 150: Command Code Modifier (Ccm)

    9.3.3 Access Identifier (aid) The access identifier (aid) parameter uniquely identifies an object within the ONS 15216 EDFA2. For the ONS 15216 EDFA2, there are four specific aids (1, PWR-A, PWR-B, EQPT) and the ALL aid, as described in Table command inputs that require an aid as a mandatory parameter, the ALL aid is accepted as well as any relevant specific aids.
  • Page 151: Summary Of Autonomous Alarms And Messages

    Table 9-3 TL1 Notation Symbols Symbol < > text 9.5 Summary of Autonomous Alarms and Messages Table 9-4 summarizes the ONS 15216 EDFA2 autonomous alarms. Table 9-4 TL1 Autonomous Alarms TL1 Autonomous Message REPT ALM DWDM REPT ALM DWDM REPT ALM DWDM...
  • Page 152: Table 9-5 Tl1 Autonomous Events

    1. The messages for Loss of Signal (LOS), Gain Out of Range (GAIN), and Loss of Output Power (LPOUT) are prioritized (in the order just listed) so that only one message can be delivered at one time. For example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at the same time, it will deliver only the Loss of Signal (LOS) message to the user.
  • Page 153 REPT ALM EQPT REPT ALM EQPT 78-16033-01 Condition Type Condition Descriptor (condtype) (conddescr) SOFTWARELOAD (New) Software Load SOFTWARERESET Software Reset summarizes the ONS 15216 EDFA2 file transfer events. File Transfer File Transfer Access Status Result Identifier (fxfr_status) (fxfr_rslt) (aid) START...
  • Page 154: Summary Of Security Permissions For Tl1 Commands

    DLT-RFILE DLT-USER-SECU ED-DAT ED-DWDM ED-ENV ED-NE-GEN ED-PID ED-USER-SECU ENT-USER-SECU INH-MSG-ALL INIT-SYS Cisco ONS 15216 EDFA2 Operations Guide Description Activates user session (login). ACT-USER, page 9-9. Allows automatic (REPT) messages. ALW-MSG-ALL, page 9-9. Applies software cutover. APPLY, page 9-11. Cancels user session (logoff).
  • Page 155 Retrieves condition (state) of current power-bus alarms. RTRV-COND-ENV, page 9-44. Retrieves condition (state) of current general alarms. RTRV-COND-EQPT, page 9-46. Retrieves timeouts for access levels. RTRV-DFLT-SECU, page 9-47. Retrieves optical parameters. RTRV-DWDM, page 9-48. Cisco ONS 15216 EDFA2 Operations Guide User Access Levels...
  • Page 156: Table 9-8 Tl1 Commands And Messages Security Permissions (Access Levels)

    RTRV-TH-ENV RTRV-TH-EQPT RTRV-TOD RTRV-USER-SECU SET-ATTR-SECUDFLT Sets timeout values for access levels. SET-TH-DWDM SET-TH-ENV SET-TH-EQPT STA-LOCL-RST Cisco ONS 15216 EDFA2 Operations Guide Description Retrieves power bus mode. RTRV-ENV, page 9-50. Retrieves header (pings NE). RTRV-HDR, page 9-51. Retrieves inventory parameters. RTRV-INV, page 9-51.
  • Page 157: Tl1 Commands And Autonomous Messages

    Command ALW-MSG-ALL Permits or resumes the dispatch of automatic messages from the ONS 15216 EDFA2 that were inhibited by an INH-MSG call. All alarms in existence at the time that this command restores them are transmitted via REPT ALM and REPT EVT messages.
  • Page 158: Table 9-10 Alw-Msg-All Syntax Description

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L Table 9-10 ALW-MSG-ALL Syntax Description Parameter ntfncde condtype Cisco ONS 15216 EDFA2 Operations Guide 9-10 Syntax Description Notification code of the alarm or event that is to be allowed (maps to cerent15216EdfaAlarmPriority for active alarms).
  • Page 159: Apply

    “Min Case Temperature Changed” (cerent15216EdfaCtmpMin). MINCTMPHYSTCHGD “Min Ctmp (case temperature) Hysteresis Changed” (cerent15216EdfaCtmpMinHysteresis). CUTOVERRESET (Software) “Reset after Cutover” (cerent15216EdfaOpCutover). SOFTWARELOAD (New) “Software Load” (cerent15216EdfaOpLoad). SOFTWARERESET “Software Reset” (cerent15216EdfaOpReset). All condtype preceding. TL1 Commands and Autonomous Messages Cisco ONS 15216 EDFA2 Operations Guide 9-11...
  • Page 160: Canc-User

    APPLY command), to copy a remote or local file to the ONS 15216 EDFA2 flash file system, or to copy a file on the ONS 15216 EDFA2 flash file system to a remote or local file. There may be a delay while this command executes.
  • Page 161: Table 9-12 Copy-Rfile Syntax Description

    78-16033-01 Syntax Description Specifies the type and direction of transfer. Possible values are: Restore a file from remote server to the ONS 15216 EDFA2’s flash file system. RFBU Backup a file from the ONS 15216 EDFA2’s flash file system to the remote server (overwrite is always YES for this type).
  • Page 162: Cpy-Mem

    ONS 15216 EDFA2 system configuration file, only when fromdev is specified to be DBCFG or null. ONS 15216 EDFA2 system log file, only when fromdev is specified to be MEM or null. any other string The name of the source file when fromdev is specified to be FFS.
  • Page 163: Dlt-Rfile

    Table 9-13 CPY-MEM Syntax Description (continued) Parameter fromdev tofile 9.7.7 DLT-RFILE Command DLT-RFILE Deletes a file from the flash file system (FFS) of the ONS 15216 EDFA2. Syntax DLT-RFILE:[<tid>]::<ctag>::FILE=<localfilename>; Example 9-9 Amp01:ONS15216 EDFA2> DLT-RFILE:Amp01::1234::FILE=snmp.cfg; Table 9-14 DLT-RFILE Syntax Description Parameter...
  • Page 164: Dlt-User-Secu

    Example 9-10 DLT-USER-SECU Command Amp01:ONS15216 EDFA2> DLT-USER-SECU:Amp01:jsmith:123; Table 9-15 DLT-USER-SECU Syntax Description Parameter 9.7.9 ED-DAT Command ED-DAT Edits the date and/or time of the ONS 15216 EDFA2. Syntax ED-DAT:[<tid>]::<ctag>::<utcdate>,<utctime>; Example 9-11 ED-DAT Command Amp01:ONS15216 EDFA2> ED-DAT:Amp01::123::2001-12-18,02-24-55; Table 9-16 ED-DAT Syntax Description Parameter...
  • Page 165: Ed-Dwdm

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L 9.7.10 ED-DWDM Command ED-DWDM Configures the ONS 15216 EDFA2 optical control parameters. Syntax ED-DWDM:[<tid>]:<aid>:<ctag>:::[PUMP1CTRLMODE=<pump1ctrlmode>],[PUMP1CTRLVALUE=<pump1ctrlv alue>],[PUMP2CTRLMODE=<pump2ctrlmode>],[PUMP2CTRLVALUE=<pump2ctrlvalue>],[OVERALLGAIN=<gai n>],[PREATT=<preatt>];...
  • Page 166: Ed-Env

    Parameter pump1ctrlvalue, pump2ctrlvalue gain preatt 9.7.11 ED-ENV Command ED-ENV Configures the ONS 15216 EDFA2 environmental (power bus) parameters. Syntax ED-ENV:[<tid>]:<aid>:<ctag>:::PWRBUSMODE=<pwrbusmode>; Example 9-13 ED-ENV Command Amp01:ONS15216 EDFA2> ED-ENV:Amp01:ALL:123:::PWRBUSMODE=SIMPLEX; Table 9-18 ED-ENV Syntax Description Parameter Cisco ONS 15216 EDFA2 Operations Guide 9-18...
  • Page 167: Ed-Ne-Gen

    (target identifier), IP address, IP mask, and IP address of the default router. The ONS 15216 EDFA2 needs to be manually rebooted for the changes to take effect. (Use the INIT-SYS command to manually reboot after changing parameters.) Also edits the boot table content: to return to the TL1 shell from the ASH shell, use the ASH command shell type modify tl1 (step RS-232 (EIA/TIA-232) Port Using HyperTerminal”...
  • Page 168: Ed-Pid

    Default type of command line interface for all EIA/TIA-232 and default telnet port user sessions with the ONS 15216 EDFA2. Possible values are: TL1shell interface (manufacturer default). ASH shell interface – ONS 15216 EDFA2’s native interface. Syntax Description string The user’s identifier (user name).
  • Page 169: Ed-User-Secu

    New access level of the user. See Permissions for TL1 Commands” section on page 9-6 access level permissions. Read only privileges. Read and write privileges. Read, write, and administrative privileges. TL1 Commands and Autonomous Messages “Summary of Security Cisco ONS 15216 EDFA2 Operations Guide 9-21...
  • Page 170: Inh-Msg-All

    Table 9-22 ENT-USER-SECU Syntax Description Parameter 9.7.16 INH-MSG-ALL Command INH-MSG-ALL Prohibits the dispatch of some automatic messages from the ONS 15216 EDFA2 as specified in the parameters. Does not affect response from RTRV commands. Syntax INH-MSG-ALL:[<tid>]::<ctag>::[<ntfcncde>],[<condtype>][,]; Example 9-18 INH-MSG-ALL Command Amp01:ONS15216 EDFA2>...
  • Page 171 “Power Bus A (voltage) Alarm” (cerent15216EdfaAlarmPowerBusA). POWERBUSB “Power Bus B (voltage) Alarm” (cerent15216EdfaAlarmPowerBusB). CTRLMODE1 “Pump1 Control Mode Changed” (cerent15216EdfaControlMode for cerent15216EdfaPumpCfgPumpNumber=1). CTRLMODE2 “Pump2 Control Mode Changed” (cerent15216EdfaControlMode for cerent15216EdfaPumpCfgPumpNumber=2). TL1 Commands and Autonomous Messages Cisco ONS 15216 EDFA2 Operations Guide 9-23...
  • Page 172 F I N A L D R A F T - C I S C O C O N F I D E N T I A L Table 9-23 INH-MSG-ALL Syntax Description (continued) Parameter Cisco ONS 15216 EDFA2 Operations Guide 9-24 Syntax...
  • Page 173: Init-Sys

    (in the order just listed) so that only one message can be delivered at one time. For example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at the same time, it will deliver only the Loss of Signal message to the user.
  • Page 174: Table 9-25 Rept Alm Dwdm Syntax Description

    Cisco ONS 15216 EDFA2 Operations Guide 9-26 Syntax Description hh:mm:ss Time of origination of TL1 message. The alarm severity code for the TL1 message. Possible values are: Critical alarm. Major alarm.
  • Page 175: Rept Alm Env

    Possible condtype and corresponding conddescr (in quotes) are: PWRBUSA “Power Bus A (voltage) Alarm” (cerent15216EdfaAlarmPowerBusA). PWRBUSB “Power Bus B (voltage) Alarm” (cerent15216EdfaAlarmPowerBusB). yyyy-mm-dd Date of origination of TL1 message. TL1 Commands and Autonomous Messages Cisco ONS 15216 EDFA2 Operations Guide 9-27...
  • Page 176: Rept Alm Eqpt

    <almcde> <atag> REPT ALM EQPT "<aid>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,:<conddescr>" Example 9-22 REPT ALM EQPT Message Amp01 2001-06-18 14:48:44 141 REPT ALM EQPT "EQPT:MN,LCRNT1,NSA,6-18,14-48-44,,:\"Excessive Pump1 Current\"" Cisco ONS 15216 EDFA2 Operations Guide 9-28 Syntax Description Notification code (maps to cerent15216EdfaAlarmPriority). Possible values are: Critical alarm.
  • Page 177: Table 9-27 Rept Alm Eqpt Syntax Description

    . Always EQPT. EQPT General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus). Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below.
  • Page 178: Rept Evt Dwdm / Rept Evt Env / Rept Evt Eqpt

    <atag> REPT EVT <ccm> "<aid>:<condtype>,<condeff>,<ocrdat>,<ocrtm>,,,,:<conddescr>" Example 9-23 REPT EVT DWDM Message Amp01 2001-06-18 14:48:44 141 REPT EVT DWDM "1:CTRLMODE1,TC,6-18,14-48-44,,,,:\"Pump1 Control Mode Changed\"" Cisco ONS 15216 EDFA2 Operations Guide 9-30 Syntax Description Effect on service. Possible values are: Service affecting. Non-service affecting.
  • Page 179: Table 9-28 Rept Evt Dwdm / Rept Evt Env / Rept Evt Eqpt Syntax Description

    PWR-B Affecting Power Bus B. EQPT General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus). Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below.
  • Page 180: Rept Evt Fxfr

    Reports autonomous events related to the FTP file transfer (see Reports when an event related to the file transfer is logged. Syntax <sid> <date> <time> <atag> REPT EVT FXFR "<aid>:<filename>,<fxfr_status>[,<fxfr_rslt>][,<bytes_xfrd>]" Cisco ONS 15216 EDFA2 Operations Guide 9-32 Syntax Description MAXCTMPHYSTCHGD “Max Ctmp (case temperature) Hysteresis Changed”...
  • Page 181: Rtrv-Alm-All

    (LPOUT) are prioritized (in the order just listed) so that only one message can be delivered at one time. For example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at the same time, it will deliver only the Loss of Signal (LOS) message to the user.
  • Page 182: Table 9-30 Rtrv-Alm-All Syntax Description

    Possible values are: Directly affecting the optical signal EQPT General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus) Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text. See condtype below Condition type identifies the type of alarm (maps to cerent15216EdfaLogEventID).
  • Page 183: Rtrv-Alm-Dwdm

    (LPOUT) are prioritized (in the order just listed) so that only one message can be delivered at one time. For example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at the same time, it will deliver only the Loss of Signal (LOS) message to the user.
  • Page 184: Table 9-31 Rtrv-Alm-Dwdm Syntax Description

    Cisco ONS 15216 EDFA2 Operations Guide 9-36 Syntax Description 1 and ALL have same input effect. Directly affecting the optical signal. Any or all of the preceding (command input only). Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text.
  • Page 185: Rtrv-Alm-Env

    “Power Bus B (voltage) Alarm” (cerent15216EdfaAlarmPowerBusB). yyyy-mm-dd Date of origination of TL1 message. Notification code (maps to cerent15216EdfaAlarmPriority). Possible values are: Critical alarm. Major alarm. Minor alarm. Cleared alarm. No alarm. TL1 Commands and Autonomous Messages Cisco ONS 15216 EDFA2 Operations Guide 9-37...
  • Page 186: Rtrv-Alm-Eqpt

    Description EQPT and ALL have same input effect. EQPT General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus). Any or all of the preceding (command input only). Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text.
  • Page 187 Source identifier uniquely identifies the source of a TL1 autonomous command. Effect on service. Possible values are: Service affecting. Non-service affecting. hh:mm:ss Time of origination of TL1 message. TL1 Commands and Autonomous Messages Cisco ONS 15216 EDFA2 Operations Guide 9-39...
  • Page 188: Rtrv-Ao

    Description atag is an integer between 0 and 999 used by the ONS 15216 EDFA2 to sequentially number in autonomous messages. atagseq can be a single atag number or a range of numbers in the form AA&&BB, where AA and BB are integers.
  • Page 189: Rtrv-Cond-All

    (LPOUT) are prioritized (in the order just listed) so that only one message can be delivered at one time. For example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at the same time, it will deliver only the Loss of Signal (LOS) message to the user.
  • Page 190 (ccm) date ntfncde ocrdat ocrtm srveff time Cisco ONS 15216 EDFA2 Operations Guide 9-42 Syntax Description Condition type identifies the type of alarm (maps to cerent15216EdfaLogEventID). Possible condtype and corresponding conddescr (in quotes) are: “Loss of Signal” (input power) alarm (DWDM) (cerent15216EdfaAlarmLpin).
  • Page 191: Rtrv-Cond-Dwdm

    (LPOUT) are prioritized (in the order just listed) so that only one message can be delivered at one time. For example, if the ONS 15216 EDFA2 detects both a loss of input signal and a loss of output power at the same time, it will deliver only the Loss of Signal (LOS) message to the user.
  • Page 192: Rtrv-Cond-Env

    <ctag> COMPLD "<aid>,<ccm>:<ntfcncde>,<condtype>,<srveff>,<ocrdat>,<ocrtm>,,,<conddescr>" Example 9-32 RTRV-COND-ENV Command and Response Amp01:ONS15216 EDFA2> RTRV-COND-ENV:Amp01:ALL:229::PWRBUSA; Amp01 2002-06-20 14:30:00 229 COMPLD "PWR-A,ENV:MN,PWRBUSA,NSA,6-20,14-25-30,,,\"Power Bus A Alarm\"" Cisco ONS 15216 EDFA2 Operations Guide 9-44 Syntax Description Notification code (maps to cerent15216EdfaAlarmPriority). Possible values are: Critical alarm.
  • Page 193: Table 9-37 Rtrv-Cond-Env Syntax Description

    Source identifier uniquely identifies the source of a TL1 autonomous command. Effect on service. Possible values are: Service affecting. Non-service affecting. hh:mm:ss Time of origination of TL1 message. TL1 Commands and Autonomous Messages Cisco ONS 15216 EDFA2 Operations Guide 9-45...
  • Page 194: Rtrv-Cond-Eqpt

    Description EQPT and ALL have same input effect. EQPT General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus). Any or all of the preceding (command input only). Detailed text description of the event. The conddescr is 1 to 64 characters of ASCII text.
  • Page 195: Rtrv-Dflt-Secu

    Source identifier uniquely identifies the source of a TL1 autonomous command. Effect on service. Possible values are: Service affecting. Non-service affecting. hh:mm:ss Time of origination of TL1 message. TL1 Commands and Autonomous Messages Cisco ONS 15216 EDFA2 Operations Guide 9-47...
  • Page 196: Rtrv-Dwdm

    Time of origination of TL1 message. EQPT and ALL have same input effect. EQPT General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus). Any or all of the preceding (command input only). Access level of the user. See for TL1 Commands”...
  • Page 197: Table 9-40 Rtrv-Dwdm Syntax Description

    0 - 100 Pump power in mW when mode is PWR (gets cerent15216EdfaPumpCfgConstPumpPower). 0 - 230 Value of gain in units of 10 dB when mode is GAINTEMP (gets cerent15216EdfaConstGainOverallGainMeasured). TL1 Commands and Autonomous Messages Cisco ONS 15216 EDFA2 Operations Guide 9-49...
  • Page 198: Rtrv-Env

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L Table 9-40 RTRV-DWDM Syntax Description (continued) Parameter gain preattmeasured 9.7.34 RTRV-ENV Command RTRV-ENV Retrieves the ONS 15216 EDFA2 environmental parameter configuration. Syntax RTRV-ENV:[<tid>]:<aid>:<ctag>; <sid> <date> <time> <ctag> COMPLD "<aid>:PWRBUSMODE=<pwrbusmode>" Example 9-36 RTRV-ENV Command and Response Amp01:ONS15216 EDFA2>...
  • Page 199: Rtrv-Hdr

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L 9.7.35 RTRV-HDR Command RTRV-HDR Retrieves header. Sends standard keep-alive message used to ping the ONS 15216 EDFA2. It also returns the current date, time, and sid/tid name of the ONS 15216 EDFA2 in the reply. Syntax RTRV-HDR:[<tid>]::<ctag>;...
  • Page 200: Rtrv-Ne-Gen

    9.7.37 RTRV-NE-GEN Command RTRV-NE-GEN Retrieves general parameters of the ONS 15216 EDFA2. Retrieves sid/tid name, IP address and mask, and default router information. Also retrieves the boot table content. Syntax RTRV-NE-GEN:[<tid>]::<ctag>; <sid> <date> <time> <ctag> COMPLD "<aid>:NAME=<name>,IPADDR=<ipaddr>,IPMASK=<ipmask>,DEFRTR=<defrtr>, BOOTRECORDTYPE1=<bootrectype1>, BOOTFILENAME1=<bootfilename1>,BOOTIPADDR1=<bootipaddr1>,...
  • Page 201: Table 9-44 Rtrv-Ne-Gen Syntax Description

    78-16033-01 Syntax Description Always EQPT. EQPT General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus). string System’s sid/tid name (sysName). string IP address of the system (cerent15216EdfaSromIpMgmtEnetAddress). string Subnet mask of the system (cerent15216EdfaSromIpMgmtEnetSubNetMask).
  • Page 202: Rtrv-Rfile

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L 9.7.38 RTRV-RFILE Command RTRV-RFILE Lists a specific file or all files on the flash file system of the ONS 15216 EDFA2. Syntax RTRV-RFILE:[<tid>]::<ctag>::[<localfilename>+]; <sid> <date> <time>...
  • Page 203: Rtrv-Th-Dwdm

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L 9.7.39 RTRV-TH-DWDM Command RTRV-TH-DWDM Retrieves optical threshold and set point values for the ONS 15216 EDFA2. Syntax RTRV-TH-DWDM:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,][,]; <sid> <date> <time>...
  • Page 204: Rtrv-Th-Env

    Table 9-46 RTRV-TH-DWDM Syntax Description (continued) Parameter threshholdtype thresholdvalue pairs 9.7.40 RTRV-TH-ENV Command RTRV-TH-ENV Retrieves threshold values of the environmental (power bus) parameters of the ONS 15216 EDFA2. Syntax RTRV-TH-ENV:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,]; <sid> <date> <time> <ctag> COMPLD "<aid>,ENV:<thresholdtype>,,,<thresholdvalue>" Cisco ONS 15216 EDFA2 Operations Guide 9-56...
  • Page 205: Rtrv-Th-Eqpt

    Table 9-47 RTRV-TH-ENV Syntax Description Parameter date time threshholdtype thresholdvalue pairs 9.7.41 RTRV-TH-EQPT Command RTRV-TH-EQPT Retrieves general threshold values for the ONS 15216 EDFA2. Syntax RTRV-TH-EQPT:[<tid>]:<aid>:<ctag>::[<thresholdtype>][,][,]; <sid> <date> <time> <ctag> COMPLD "<aid>:<thresholdtype>,,,<thresholdvalue>" 78-16033-01 Syntax Description yyyy-mm-dd Date of origination of TL1 message.
  • Page 206: Table 9-48 Rtrv-Th-Eqpt Syntax Description

    Time of origination of TL1 message. EQPT and ALL have same input effect. EQPT General parameters of the ONS 15216 EDFA2 (not directly affecting optical signal or power bus). Any or all of the preceding (command input only). Type of threshold or set point that is to be retrieved. A null value is equivalent to ALL.
  • Page 207: Rtrv-Tod

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L 9.7.42 RTRV-TOD Command RTRV-TOD Retrieves the date and time of the ONS 15216 EDFA2. Syntax RTRV-TOD:[<tid>]::<ctag>[::]; <sid> <date> <time>...
  • Page 208: Rtrv-User-Secu

    Sets the timeout value of user sessions for users with a specific access level. If no communication occurs for this time, the user session is closed by the ONS 15216 EDFA2 TL1 agent. Users affected by changes to the timeout must log out and log in again for the change to take effect.
  • Page 209: Set-Th-Dwdm

    Example 9-47 SET-ATTR-SECUDFLT Command Amp01:ONS15216 EDFA2> SET-ATTR-SECUDFLT:Amp01::123::AL=RW,TMOUT=45; Table 9-51 SET-ATTR-SECUDFLT Syntax Description Parameter timeout 9.7.45 SET-TH-DWDM Command SET-TH-DWDM Sets optical threshold values for the ONS 15216 EDFA2. Syntax SET-TH-DWDM:[<tid>]:<aid>:<ctag>::<thresholdtype>,<thresholdvalue>[,,]; Example 9-48 SET-TH-DWDM Command Amp01:ONS15216 EDFA2> SET-TH-DWDM:Amp01:ALL:123::LOSTH,-1500; Table 9-52 SET-TH-DWDM Syntax Description Parameter 78-16033-01...
  • Page 210: Set-Th-Env

    Parameter threshholdtype thresholdvalue pairs 9.7.46 SET-TH-ENV Command SET-TH-ENV Sets threshold values of the environmental (power bus) parameters of the ONS 15216 EDFA2. Syntax SET-TH-ENV:[<tid>]:<aid>:<ctag>::<thresholdtype>,<thresholdvalue>[,,]; Example 9-49 SET-TH-ENV Command Amp01:ONS15216 EDFA2> SET-TH-ENV:Amp01:PWR-A:100::PWRBUSMIN,450; Table 9-53 SET-TH-ENV Syntax Description Parameter Cisco ONS 15216 EDFA2 Operations Guide...
  • Page 211: Set-Th-Eqpt

    Table 9-53 SET-TH-ENV Syntax Description (continued) Parameter threshholdtype thresholdvalue pairs 9.7.47 SET-TH-EQPT Command SET-TH-EQPT Sets general threshold values for the ONS 15216 EDFA2. Syntax SET-TH-EQPT:[<tid>]:<aid>:<ctag>::<thresholdtype>,<thresholdvalue>[,,]; Example 9-50 SET-TH-EQPT Command Amp01:ONS15216 EDFA2> SET-TH-EQPT:Amp01:ALL:123::MAXCTMP,60; Table 9-54 SET-TH-EQPT Syntax Description Parameter 78-16033-01 Syntax Description Type of threshold that is to be set.
  • Page 212: Sta-Locl-Rst

    Command STA-LOCL-RST Instructs the ONS 15216 EDFA2 to restore all the manufacturing default settings. The files on the flash file system (FFS), the date and time, the sid/tid name (name), and the values of manufacturing calibration are not affected. This command must be followed by the INIT-SYS command to take effect.
  • Page 213: Chapter 10 Troubleshooting

    Troubleshooting This chapter presents basic fault information and diagnosis (troubleshooting) procedures for the 2.1.0, 2.2.1, and 2.3.0 product releases of the Cisco ONS 15216 EDFA2. Only TL1 information about the alarm notifications and commands is provided. This chapter describes the behavior of the ONS 15216 EDFA2 in the most expected troubleshooting situations.
  • Page 214: Alarm Indicators

    • On the left side of the front panel of the ONS 15216 EDFA2 are the POWER, FAIL, and LOS alarm LEDs. The Ethernet LEDs are located at the top left and right sides of the Ethernet LAN port. When the module is powered on, a LED test is performed.
  • Page 215 Off: The optical input power is above the user-settable minimum threshold (or –48 VDC power has • failed). On: LOS alarm. The optical input power to the ONS 15216 EDFA2 is below the threshold defined • by LOSTH . The value of LOSHYST provides the hysteresis required for the alarm to clear.
  • Page 216: Optical Alarms

    10.1.2.2 GAIN (Gain Out of Range) Alarm This alarm is only valid when the ONS 15216 EDFA2 is in GAINTEMP mode. It occurs when the value of OVERALLGAINMEASURED has deviated more than 1.25 dB from the manufacturer-defined set point’s allowable range.
  • Page 217 10.1.2.3 LPOUT (Loss of Output Power) Alarm This alarm is valid only when the ONS 15216 EDFA2 is in OPWR mode, which is rare because this mode applies to few applications and is generally not recommended. This alarm occurs if the unit is in OPWR mode and the output power is deviating more than the value of LPOUTDEV from the value of LPOUTSETPT.
  • Page 218: Equipment Alarms

    The ambient temperature is too high for a legitimate case temperature alarm to clear: Shut down the • ONS 15216 EDFA2 and allow time for it to cool, and do not repower it until the ambient temperature is reduced. 10.1.3.2 LCRNT1 and LCRNT2 (Excessive Pump Current) Alarms These alarms occur when the input power exceeds input range and the ONS 15216 EDFA2 is overdriving the pump laser to try to get the target Gain value.
  • Page 219: Environmental Alarms

    F I N A L D R A F T - C I S C O C O N F I D E N T I A L 10.1.4 Environmental Alarms The ONS 15216 EDFA2 amplifier has three main categories of alarms: optical (DWDM), equipment (EQPT), and environmental (ENV). The environmental alarms are directly related to the power bus voltage.
  • Page 220: To 2.2.1 Upgrade Attempt

    2.1.0, 2.2.1, and 2.3.0 Release Notes for the procedures. 10.2.4 Boot Up Failure If the primary image fails to boot, the ONS 15216 EDFA2 boots the second image. If both fail, the ONS 15216 EDFA2 continues to try to alternately boot the images unsuccessfully.
  • Page 221: No Response From Rs-232 Port

    10.2.6 No Response from LAN Port If the ONS 15216 EDFA2 does not respond on the RJ-45 LAN port, check that the physical connection is good, that power is supplied to the unit (POWER LED is on or flashing), that the IP address and subnet mask are correct (RTRV-NE-GEN command from RS-232 port), and that the application (Telnet) is trying to access the correct IP address.
  • Page 222: Lost Password

    If the root password for CISCO15 is lost, there is a procedure to reset it to regain full administrative control of the ONS 15216 EDFA2. The user must be connected to the ONS 15216 EDFA2 by serial communication, reset the power to the unit, and perform a series of commands within 60 seconds of rebooting, according to the following procedure.
  • Page 223: Status Information Needed By Cisco Tac

    10.3 Status Information Needed by Cisco TAC To get the most from an interaction with the Cisco Technical Assistance Center (TAC), the status information of the ONS 15216 EDFA2 should be collected in advance. The following commands should be issued, and pasted into a text file.
  • Page 224 Status Information Needed by Cisco TAC F I N A L D R A F T - C I S C O C O N F I D E N T I A L Cisco ONS 15216 EDFA2 Operations Guide 10-12...
  • Page 225: Appendix

    December 1997, with Revision 1, February 1999 Sections 2 and 3 VCCI V-1/93. 11, V-2/97. 04, V-4/97, R-1225 and C-1287 Cisco ONS 15216 EDFA2 Operations Guide Description Power supply interface at the input to telecommunications equipment; Part 2: Operated by direct current (DC)
  • Page 226: A P P E N D I X A Regulatory Compliance And Safety Information

    Italian Norwegian Portuguese Spanish Swedish Chinese (not all warnings translated) Japanese (not all warnings translated) Korean (not all warnings translated) Cisco ONS 15216 EDFA2 Operations Guide Appendix A Standard IEC 60950 EN 60950 UL 60950 CSA-C22.2 No. 60950 TS 001...
  • Page 227: Warning Definition

    • Cisco ONS 15216 EDFA2 Temperature Requirement • VCCI Compliance for Class B Equipment • SELV-IEC 60950 DC Power Supply Warning • Cisco ONS 15216 EDFA2 Power Circuit Overload Warning • Product Disposal Warning • Energy Hazard • • Unit Grounding Protection Warning •...
  • Page 228 Tässä julkaisussa esiintyvien varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta). Cisco ONS 15216 EDFA2 Operations Guide Appendix A Regulatory Compliance and Safety Information 78-16033-01...
  • Page 229 Se förklaringar av de varningar som förkommer i denna publikation i dokumentet Regulatory Compliance and Safety Information (Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer denna anordning. Cisco ONS 15216 EDFA2 Operations Guide 78-16033-01...
  • Page 230 När flertrådiga ledningar krävs måste godkända ledningskontakter användas, t.ex. kabelsko av sluten eller öppen typ med uppåtvänd tapp. Storleken på dessa kontakter måste vara avpassad till ledningarna och måste kunna hålla både isoleringen och ledaren fastklämda. Cisco ONS 15216 EDFA2 Operations Guide Appendix A Regulatory Compliance and Safety Information...
  • Page 231 Warnung Diese Einheit hat möglicherweise mehr als ein Netzkabel. Zur Verringerung der Stromschlaggefahr trennen Sie beide Netzgerätekabel ab, bevor Sie die Einheit warten. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide...
  • Page 232 Bevor Sie an einem System ohne Ein/Aus-Schalter arbeiten, ziehen Sie das Netzkabel heraus. Avvertenza Prima di lavorare su un sistema che non è dotato di un interruttore on/off, scollegare il cavo di alimentazione. Cisco ONS 15216 EDFA2 Operations Guide Appendix A Regulatory Compliance and Safety Information 78-16033-01...
  • Page 233 Sicherheitskreise mit Sicherheitskleinspannung (Safety Extra-Low Voltage, SELV). SELV-Kreise sollten ausschließlich an andere SELV-Kreise angeschlossen werden. Da die BRI-Kreise wie Telefonnetzspannungen behandelt werden, ist der SELV-Kreis nicht an Telefonnetzspannungskreise (TNV) anzuschließen. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide...
  • Page 234 Avvertenza Emissione di radiazioni laser quando il sistema è aperto. Laserstråling er til stede når enheten er åpen. Advarsel Aviso Radiação laser presente quando aberto. Cisco ONS 15216 EDFA2 Operations Guide A-10 Appendix A Regulatory Compliance and Safety Information 78-16033-01...
  • Page 235 Kiinnitä kaikki voimakaapelit tiukkaan tätä laitetta asentaessasi, jotta vältät kentän johdinkytkentöjen vioittumista. Attention Lors de l’installation de cet appareil, fixer tous les câbles d’alimentation pour éviter de provoquer des perturbations aux raccordements des câblages propres au site. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-11...
  • Page 236 ¡Advertencia! Este equipo debe conectarse a tierra. Asegurarse de que el equipo principal esté conectado a tierra durante el uso normal. Cisco ONS 15216 EDFA2 Operations Guide A-12 Appendix A Regulatory Compliance and Safety Information...
  • Page 237 ¡Advertencia! Al instalar el equipo, conectar la tierra la primera y desconectarla la última. Varning! Vid installation av enheten måste jordledningen alltid anslutas först och kopplas bort sist. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-13...
  • Page 238 är kopplad till kraftledningar. Metallobjekt hettas upp när de kopplas ihop med ström och jord och kan förorsaka allvarliga brännskador; metallobjekt kan också sammansvetsas med kontakterna. Cisco ONS 15216 EDFA2 Operations Guide A-14 Appendix A Regulatory Compliance and Safety Information...
  • Page 239: Supply Circuit Warning

    Beim Anschließen der Geräte an das Stromnetz ist darauf zu achten, daß die Schaltverbindungen nicht überlastet werden. Avvertenza Fare attenzione quando si collegano le unità al circuito di alimentazione, per non sovraccaricare i cablaggi. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-15...
  • Page 240: Power Supply Wiring Warning

    (da linea ad L) e da negativo a negativo (da neutro a N). Tenere presente che il filo di massa deve sempre venire collegato per primo e scollegato per ultimo. Cisco ONS 15216 EDFA2 Operations Guide A-16...
  • Page 241: Invisible Laser Radiation Warning

    Advarsel Usynlige laserstråler kan sendes ut fra åpningen på utgangen når ingen kabel er tilkoblet. Unngå utsettelse for laserstråling og se ikke inn i åpninger som ikke er tildekket. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-17...
  • Page 242: Incorrect Connection Warning

    La conexión incorrecta de este equipo, o del equipo conectado, a una toma o receptáculo de tipo general podría resultar en una situación peligrosa. Varning! Felaktig koppling av denna eller ansluten utrustning till ett universaluttag kan orsaka riskfylld situation. Cisco ONS 15216 EDFA2 Operations Guide A-18 Appendix A Regulatory Compliance and Safety Information 78-16033-01...
  • Page 243: Ground Conductor Warning

    Koppla aldrig från jordledningen och använd aldrig utrustningen utan en på lämpligt sätt installerad jordledning. Om det föreligger osäkerhet huruvida lämplig jordning finns skall elektrisk besiktningsauktoritet eller elektriker kontaktas. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-19...
  • Page 244: Voltages On Dc-Input Power Supply Terminals

    Varning! Spänningar kan förekomma på likströmsförsörjningsenhetens ingångspoler. Innan du skaffar dig tillträde till polerna, stäng av strömbrytaren till strömkällan och avlägsna strömförsörjningsenheten. Cisco ONS 15216 EDFA2 Operations Guide A-20 Appendix A Regulatory Compliance and Safety Information 78-16033-01...
  • Page 245: More Than One Power Supply

    Varoitus Cisco ONS 15216 EDFA2 on asennettava telineeseen, joka on kiinnitetty rakennukseen. Attention Le rack sur lequel est monté le Cisco ONS 15216 EDFA2 doit être fixé à la structure du bâtiment. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide...
  • Page 246: Exposed Dc Power Wire Warning

    Der Cisco ONS 15216 EDFA2 muß in einem Gestell installiert werden, das in der Gebäudestruktur verankert ist. Avvertenza Il Cisco ONS 15216 EDFA2 deve essere installato in un telaio, il quale deve essere fissato alla struttura dell'edificio. Advarsel Cisco ONS 15216 EDFA2 må installeres i et stativ som er forankret til bygningsstrukturen.
  • Page 247: Vdc Power System

    AC y la potencia de salida de 48 VDC. Varning! Kundens 48-volt strömsystem måste vara försett med förstärkt isolering mellan den primära växelströmmen och utmatningen av 48 V likström. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-23...
  • Page 248: Chassis Power Connection

    DESLIGADA, localize o disjuntor no painel que serve o circuito de corrente contínua e coloque-o na posição OFF (Desligado), segurando nessa posição a manivela do interruptor do disjuntor com fita isoladora. Cisco ONS 15216 EDFA2 Operations Guide A-24 Appendix A...
  • Page 249: Cisco Ons 15216 Edfa2 Temperature Requirement

    AV det överspänningsskydd som skyddar likströmskretsen och tejpa fast överspänningsskyddets omkopplare i FRÅN-läget. Cisco ONS 15216 EDFA2 Temperature Requirement To prevent a Cisco ONS 15216 EDFA2 system from overheating, do not operate it in an area that Warning exceeds the maximum recommended ambient temperature of 122°F (50°C).
  • Page 250: Vcci Compliance For Class B Equipment

    Conecte a unidade apenas à fonte da energia de CC que se encontra em conformidade com os Aviso requisitos dos circuitos de segurança de baixa tensão (SELV) constantes dos padrões de segurança baseados no IEC 60950. Cisco ONS 15216 EDFA2 Operations Guide A-26 Appendix A Regulatory Compliance and Safety Information...
  • Page 251: Cisco Ons 15216 Edfa2 Power Circuit Overload Warning

    A fim de evitar sobrecarga perigosa do circuito de fornecimento de energia, é favor ler a etiqueta na parte de trás do Cisco ONS 15216 EDFA2, onde se encontram indicados os níveis máximos de carga de energia. O não cumprimento dessas indicações pode dar origem a uma situação de perigo.
  • Page 252: Product Disposal Warning

    Para prevenir una sobrecarga eléctrica , lea las instrucciones de la etiqueta que aparece en la parte posterior del Cisco ONS 15216 EDFA2 que indica la carga máxima de potencia. Si no sigue estas indicaciones podría correr riesgos de sobrecarga.
  • Page 253: Energy Hazard

    Varning! Endast utbildad och behörig personal får utföra installation, utbyte eller service av denna utrustning. Denna utrustning kan medföra fara för elstöt. Koppla ifrån systemet innan service utförs. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-29...
  • Page 254: Unit Grounding Protection Warning

    Koppla aldrig från jordledningen och använd aldrig utrustningen utan en på lämpligt sätt installerad jordledning. Om det föreligger osäkerhet huruvida lämplig jordning finns skall elektrisk besiktningsauktoritet eller elektriker kontaktas. Cisco ONS 15216 EDFA2 Operations Guide A-30 Appendix A Regulatory Compliance and Safety Information...
  • Page 255: Dc Power Disconnection Warning

    DESLIGADA, localize o disjuntor no painel que alimenta esse transversor e coloque-o na posição OFF (Desligado) e, em seguida, segure o disjuntor nessa posição com fita isoladora. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-31...
  • Page 256: Ground Wire Warning

    Um fio terra deve ser composto de um fio único. Nunca emende dois fios para fazer um fio terra. A corrosão e a ferrugem podem afetar a emenda e tornar o aterramento inefetivo ou perigoso. Cisco ONS 15216 EDFA2 Operations Guide A-32...
  • Page 257: Directive 93/68/Eec

    Dette utstyret samsvarer med de vesentligste kravene og andre regler i direktivene 73/23/EEC og 89/336/EEC samt i tilleggsdirektiv 93/68/EEC. Português: Este equipamento satisfaz os requisitos essenciais e outras provisões das Directivas 73/23/EEC e 89/336/EEC, conforme amendados pela Directiva 93/68/EEC. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-33...
  • Page 258: Norway, Iceland And Liechtenstein

    Este equipo cumple con los requisitos esenciales y otras provisiones relevantes de la Directiva 1999/5/EC. Svenska: Denna utrustning uppfyller de väsentliga kraven och andra relevanta förordningar i Direktiv 1999/5/EC. Cisco ONS 15216 EDFA2 Operations Guide A-34 Appendix A Regulatory Compliance and Safety Information 78-16033-01...
  • Page 259: Class B Emc Warning

    Todos os requisitos e recomendações de segurança devem ser lidos por todo o pessoal antes de trabalhar no sistema. Podem ocorrer ferimentos se os requisitos e recomendações de segurança não forem seguidos. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-35...
  • Page 260: Laser Radiation Warning

    A radiação de laser representa um risco invisível, portanto deve-se evitar exposição pessoal ao feixe do laser. O pessoal deve estar qualificado em procedimentos de segurança de laser e deve usar proteção adequada para os olhos antes de trabalhar neste equipamento. Cisco ONS 15216 EDFA2 Operations Guide A-36 Appendix A...
  • Page 261: Fiber Disconnect Sequence Warning

    Varning! För att garantera personlig säkerhet vid frånkoppling av fiberkablar ska alltid in-anslutningen kopplas ifrån först och sedan utanslutningen. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-37...
  • Page 262: Optical Connector Warning

    Dek het uiteinde van de ontkoppelde uitgangsconnector onmiddellijk af om het onder spanning staande lasersignaal te inactiveren om mogelijke schade aan de ogen te vermijden en om de connector te beschermen tegen contaminatie. Cisco ONS 15216 EDFA2 Operations Guide A-38 Appendix A...
  • Page 263: Eye Damage Warning

    Spectacle, LGS Goggle, LGW Wraparound ou LGF Full-View) ou un équipement de protection équivalent caractérisé par une densité optique supérieure à 2. Consultez le spécialiste en sécurité laser de votre site. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-39...
  • Page 264: Static Electricity Warning

    électro-optique, portez toujours un bracelet de protection antistatique pour décharger l'énergie statique accumulée. Ces bracelets antistatiques sont conçus pour empêcher tout dommage matériel dû aux décharges électrostatiques. Cisco ONS 15216 EDFA2 Operations Guide A-40 Appendix A Regulatory Compliance and Safety Information...
  • Page 265: Connector Cleaning Warning

    Si vous omettez de protéger le module en le mettant hors tension, vous créez un risque de sécurité physique permanent pour vos collègues et vous-même, tout en risquant d'endommager irrémédiablement le connecteur. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-41...
  • Page 266: Cable Connection Sequence Warning

    Avvertenza Per tutelare la sicurezza personale quando si collega un cavo a fibre ottiche, collegare per primo il connettore di uscita e quindi quello di ingresso. Cisco ONS 15216 EDFA2 Operations Guide A-42 Appendix A Regulatory Compliance and Safety Information...
  • Page 267: Module Removal Warning

    La remoción de módulos comunes conlleva a fallas de tráfico. Obtenga la debida autorización antes de realizar tareas de mantenimiento. Varning! Borttagning av gemensamma moduler orsakar trafikstopp. Skaffa korrekt behörighet före eventuellt underhållsarbete. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-43...
  • Page 268: Dc Power Selv Requirement Warning

    (SELV) de conformidad con IEC 60950 y UL 60950. Varning! Matarsystemen för likström (huvud-, tilläggs- och servicebatterisystem) måste följa kraven för SELV (safety extra low voltage) i enlighet med IEC 60950 och UL 60950. Cisco ONS 15216 EDFA2 Operations Guide A-44 Appendix A Regulatory Compliance and Safety Information...
  • Page 269: Reinforced Insulation Warning

    IEC 60950 y UL 60950. Varning! Kundens 48 VDC matarsystem (huvud-, tilläggs- och servicebatterisystem) måste ha förstärkt isolering (RI) mellan huvudväxelströmskällan och 48 VDC-uteffekten i enlighet med IEC 60950 och UL 60950. 78-16033-01 Translated Safety Warnings Cisco ONS 15216 EDFA2 Operations Guide A-45...
  • Page 270: Power Supply Voltage Warning

    (Power Distribution Panel Cabling). Warnung Verkabeln Sie die Gleichstromversorgung mit den erforderlichen Kabelschuhen an den Drahtenden bzw. ohne Kabelschuhe, wie im Abschnitt zur Stromverteilerverkabelung beschrieben. Cisco ONS 15216 EDFA2 Operations Guide A-46 Appendix A Regulatory Compliance and Safety Information...
  • Page 271 Cableado del panel de distribución de alimentación. Varning! Koppla likströmsförsörjningen med lämpliga kabelskor i kopplingsänden, eller utan kabelskor, så som visas i sektionen Power Distribution Panel Cabling strömkablar för panelen. Cisco ONS 15216 EDFA2 Operations Guide A-47 78-16033-01...
  • Page 272 Regulatory Compliance and Safety Information Translated Safety Warnings F I N A L D R A F T - C I S C O C O N F I D E N T I A L Cisco ONS 15216 EDFA2 Operations Guide A-48 78-16033-01...
  • Page 273: I N D E X

    Constant Gain Temperature Compensated mode 5-26, 5-32, 5-33, 5-34, 9-17, 9-49 Constant Output Power mode 5-14 Constant Pump Current mode 5-14 Cisco ONS 15216 EDFA2 Operations Guide I N D E X 1-3, 5-14, IN-1...
  • Page 274 6-30 ENT-USER-SECU 8-11, 9-21 equipment checklist events, TL1 autonomous 9-4, 9-5 exit 6-11 Cisco ONS 15216 EDFA2 Operations Guide IN-2 ffs file list 6-14 fiber input fiber output firmware revision 6-30, 9-52 flash file system commands 6-14...
  • Page 275: Optical Specifications

    8-10, 9-58, 9-64 6-30 9-52 3-12 3-12 3-12 3-11 2-6, 3-4 9-32 5-20 5-20 4-11, 5-13 4-4, 5-17, 5-32, 9-49 4-4, 5-17, 5-31, 9-49 5-18, 5-26 4-4, 5-16, 5-30, 5-32 4-10, 8-10 4-14 Cisco ONS 15216 EDFA2 Operations Guide Index IN-3...
  • Page 276 3-11 REPT ALM DWDM 9-25 REPT ALM ENV 9-27 REPT ALM EQPT 9-28 REPT EVT DWDM 9-30 Cisco ONS 15216 EDFA2 Operations Guide IN-4 REPT EVT ENV 9-30 REPT EVT EQPT 9-30 REPT EVT FXFR 9-32 restore system 4-13, 6-31, 8-12, 9-14...
  • Page 277 6-18 snmp row display 6-19 CfgGroup 5-28, 5-29, 5-30, 5-31, 5-33 CommunityEntry OverallControl 5-26 OverallStatusGroup 5-30, 5-32 PumpStatusAmbientTemp 5-27 PumpStatusEntry 5-27 RtcDateAndTime 5-25 SromIpMgmtGroup 5-24 ViewEntry snmp row get 6-20 OverallControl 5-26 Cisco ONS 15216 EDFA2 Operations Guide Index IN-5...
  • Page 278 4-3, 4-12, 5-25, 9-19 SromIpMgmtGroup 4-3, 5-24 SromIpMgmtHostName 4-3, 4-12, 5-25 STA-LOCL-RST 9-64 telnet 4-3, 8-3 simultaneous connections Cisco ONS 15216 EDFA2 Operations Guide IN-6 temperature ambient case case alarm storage time 4-4, 5-25, 8-4, 9-16 time zone TL1 notation symbols...
  • Page 279 Index F I N A L D R A F T - C I S C O C O N F I D E N T I A L warnings, translated safety Cisco ONS 15216 EDFA2 Operations Guide IN-7 78-16033-01...
  • Page 280 Index F I N A L D R A F T - C I S C O C O N F I D E N T I A L Cisco ONS 15216 EDFA2 Operations Guide IN-8 78-16033-01...

Table of Contents