4.4 Set Date and Time
Use the snmp attribute set local cerent15216EdfaRtcDateAndTimeLocalString command to set the
date, time, and time zone. Entries must follow this format: "yyyy-m-d,h:m:s.s +h:m". Following the
space, the time zone is set as +/– hours from Greenwich Mean Time (GMT) (also designated as universal
coordinated time (UTC)) followed by a colon and minutes ahead for daylight savings. For example,
Pacific Daylight Time would be –8:60 and Greenwich Mean Time would be +0:0. See
Example 4-4
ash:hostname:ONS15216 EDFA2>
"2002-6-30,14:8:30.0 -8:60"

4.5 Set Power Bus Mode (Simplex or Duplex)

The ONS 15216 EDFA2 allows users to set a simplex (one power source–Bus A) or duplex (redundant
power source–Bus A and Bus B) Power Bus mode. Use the snmp attribute set local
cerent15216EdfaPowerBusMode command to set the desired Power Bus mode. The default mode is
duplex. See
Example 4-5
ash:hostname:ONS15216 EDFA2>

4.6 Verify Amplifier Operational Status

To ensure that the amplifier is working correctly on the optical level, you must verify the amplifier
operational status. Use the snmp table display local cerent15216EdfaOverallStatusGroup command
to verify amplifier operational status.
Example 4-6
ash:hostname:ONS15216 EDFA2> snmp table display local cerent15216EdfaOverallStatusGroup
CLASS CERENT-15216-EDFA-MIB.cerent15216EdfaOverallStatusGroup ::=
{
};
Cisco ONS 15216 EDFA2 Operations Guide
4-4
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
Step 4
through
Setting the Date and Time
Example
4-5.
Setting the Power Bus Mode
Verifying the Amplifier Operations Status
cerent15216EdfaInPoweruW =
cerent15216EdfaInPowerdBm =
cerent15216EdfaOutPowermW =
cerent15216EdfaOutPowerdBm =
cerent15216EdfaConstGainOverallGainMeasured =
cerent15216EdfaVariableGainPreAttenuationMeasured =
Step 6
in
"Log In via RS-232 (EIA/TIA-232) Port Using
4-1.
snmp attribute set local cerent15216EdfaRtcDateAndTimeLocalString
snmp attribute set local cerent15216EdfaPowerBusMode simplex
Example 4-6
displays the output of this command.
279;
-1555;
476;
678;
219;
Chapter 4
Provisioning Using ASH and SNMP
Example
10;
4-4.