[Pr. PF82_Drive recorder - Trigger operation selection (DRTM)]

Initial value
00000000h
[Pr. PF82.0_Drive recorder - Trigger mode selection]
Initial value
0h
Select the trigger mode for the drive recorder.
When [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode), the setting value of the
servo parameter is disabled.
0: Alarm trigger
1: Analog trigger/digital trigger
When "0" (alarm trigger) is set, trigger settings other than [Pr. PA23 Drive recorder desired alarm trigger setting] and [Pr.
PF84.4-5 Drive recorder - Trigger position setting] are disabled. Refer to the following table for the unavailable servo
parameters.
Servo parameter
PF82.1
PF82.2
PF82.3
PF84.0-1
PF84.2-3
PF85
PF86
[Pr. PF82.1_Drive recorder - Trigger binding condition selection]
Initial value
0h
Select the trigger binding condition for the drive recorder.
When this servo parameter is set to "0" (disabled), the settings of [PF84.2-3 Drive recorder - Trigger channel selection 2] and
[PF86 Drive recorder - Trigger level setting 2] are disabled.
When [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode), or [Pr. PF80.0] is set to
"1" and [Pr. PF82.0 Drive recorder - Trigger mode selection] is set to "0" (alarm trigger), the setting value of this servo
parameter is disabled.
0: Disabled
1: Logical AND of trigger signals
2: Logical OR of trigger signals
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Name
Drive recorder - Trigger binding condition selection
Drive recorder - Trigger operation selection 1
Drive recorder - Trigger operation selection 2
Drive recorder - Trigger channel selection 1
Drive recorder - Trigger channel selection 2
Drive recorder - Trigger level setting 1
Drive recorder - Trigger level setting 2
Setting range
Refer to the text
Setting method
Each axis
Ver.
C4
Ver.
C4
1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
Ver.
Refer to the relevant detail No.