[Pr. PF46_Vibration failure prediction - Standard deviation (VSD)]
Initial value
0 [0.1 %]
Set the vibration level standard deviation during servo motor operation.
This servo parameter is enabled when [Pr. PF34.0 Friction failure prediction warning selection] is set to "2" (enabled (manual
threshold setting)).
When [Pr. PF34.0 Friction failure prediction warning selection] is set to "1" (enabled (automatic threshold setting)), the value
will be calculated automatically from the estimated friction torque at rated speed.
[Pr. PF47_Servo motor total travel distance offset (TMO)]
Initial value
0 [10 rev], [m]
Set an offset value for machine total travel distance.
After the equipment is replaced, set this servo parameter.
[Pr. PF63_Function selection F-15 (*FOP15)]
Initial value
00000000h
[Pr. PF63.0_[AL. 01A.5 Servo motor combination error 3] selection]
Initial value
0h
Select whether to enable or disable [AL. 01A.5 Servo motor combination error 3] for when a servo motor with a batteryless
absolute position encoder is replaced.
0: Enabled
1: Disabled
With "1" (disabled) selected, connecting a servo motor that had not been connected at the startup of the absolute position
detection system triggers [AL. 025.1 Servo motor encoder absolute position erased] instead of [AL. 01A.5 Servo motor
combination error 3].
Connecting a servo motor other than the ones with a batteryless absolute position encoder triggers [AL. 01A.5].
[Pr. PF63.1_[AL. 01A.6 Servo motor combination error 4] selection]
Initial value
0h
Select whether to enable or disable [AL. 01A.6 Servo motor combination error 4] for when a servo motor with a batteryless
absolute position encoder is replaced.
0: Enabled
1: Disabled
With "1" (disabled) selected, connecting a servo motor that had not been connected at the startup of the absolute position
detection system triggers [AL. 025.2 Scale measurement encoder - Absolute position erased] instead of [AL. 01A.6 Servo
motor combination error 4].
Connecting a servo motor other than the ones with a batteryless absolute position encoder triggers [AL. 01A.6].
1 SERVO PARAMETER DETAILS
100
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
Setting range
0 to 20000
Setting range
0 to 4294967295
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Setting method
Each axis
Setting method
Each axis
Setting method
Each axis
Ver.
D0
Ver.
D0
Ver.
C4
Ver.
C4
Ver.
Refer to the relevant detail No.