[Pr. PA02.4_Simple converter selection]
Initial value
0h
When using the simple converter, set this servo parameter.
The simple converter and external regenerative option can be used together. When using an external regenerative option, set
the regenerative option to be used with [Pr. PA02.0-1].
When [Pr. PA02.0-1 Regenerative option selection] is set to "01" (FR-XC-(H)), setting this servo parameter to "1" (enabled)
triggers [AL. 037 Parameter error].
0: Simple converter is not used
1: MR-CM3K
[Pr. PA02.5_Excessive regeneration warning enabled/disabled selection]
Initial value
0h
When [Pr. PA02.4] is set to "0" (simple converter is not used), setting this servo parameter to "1" (disabled) triggers [AL. 037
Parameter error].
When the simple converter is used, whether to enable or disable the detection of [AL. 0E0.1 Excessive regeneration warning]
is selectable with this servo parameter.
0: Enabled
1: Disabled
1 SERVO PARAMETER DETAILS
14
1.2 Basic setting servo parameters group ([Pr. PA_ _ ])
Setting range
Refer to the text
Setting range
Refer to the text
Ver.
C4
Ver.
C4