[Pr. PF81_Drive recorder - Sampling operation selection (DRMS)]

Initial value
00000000h
[Pr. PF81.0_Drive recorder - Sampling start selection]
Initial value
0h
Set this servo parameter to start drive recorder sampling.
When [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode), the setting value of the
servo parameter is disabled.
When this servo parameter is set to "1" or "2", if the settings of [Pr. PF80.2-3 Drive recorder - Sampling cycle selection] and
[Pr. PF82 Drive recorder - Trigger operation selection] to [Pr. PF94 Drive recorder - Digital channel setting 4] are changed, the
changed settings are not applied to the drive recorder. To apply the settings, cycle the power, reset the software, or set this
servo parameter to "0" (stop sampling), then set "1" or "2" again.
The storage area of the servo amplifier has a limit for the number of writings. If the trigger conditions that have been set in [Pr.
PF82] are frequently met, do not continue using this servo parameter when it is set to "2" (continuous sampling).
0: Stop sampling
1: Start a single sampling
2: Start a consecutive sampling
When "1" (start a single sampling) is set, if the trigger conditions are fulfilled after sampling starts, the drive recorder will
operate to save data once. After the data has been saved, this servo parameter will be "0" automatically.
When "2" (start a consecutive sampling) is set, if the trigger conditions are fulfilled after sampling starts, the drive recorder will
operate to save data. After that, sampling will start again.

[Pr. PF82_Drive recorder - Trigger operation selection (DRTM)]

Initial value
00000000h
[Pr. PF82.0_Drive recorder - Trigger mode selection]
Initial value
0h
Select the trigger mode for the drive recorder.
When [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode), the setting value of the
servo parameter is disabled.
0: Alarm trigger
1: Analog trigger/digital trigger
When "0" (alarm trigger) is set, trigger settings other than [Pr. PA23 Drive recorder desired alarm trigger setting] and [Pr.
PF84.4-5 Drive recorder - Trigger position setting] are disabled. Refer to the following table for the unavailable servo
parameters.
Servo parameter
PF82.1
PF82.2
PF82.3
PF84.0-1
PF84.2-3
PF85
PF86
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Name
Drive recorder - Trigger binding mode selection
Drive recorder - Trigger operation selection 1
Drive recorder - Trigger operation selection 2
Drive recorder - Trigger channel selection 1
Drive recorder - Trigger channel selection 2
Drive recorder - Trigger level setting 1
Drive recorder - Trigger level setting 2
Ver.
Refer to the relevant detail No.
Ver.
A4
Ver.
Refer to the relevant detail No.
Ver.
A4
1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
1
85

Advertisement

Table of Contents
loading

Table of Contents