[Pr. Pf21_Drive Recorder Switching Time Setting (Drt)]; [Pr. Pf23_Vibration Tough Drive - Oscillation Detection Level (Oscl1)]; [Pr. Pf24_Function Selection F-9 (*Fop9)] - Mitsubishi Electric MELSERVO MR-J5W-B Series User Manual

Hide thumbs Also See for MELSERVO MR-J5W-B Series:
Table of Contents

Advertisement

[Pr. PF21_Drive recorder switching time setting (DRT)]

Initial value
0 [s]
Set the drive recorder switching time.
When communication is shut off during the use of a graph function, the function will be switched to the drive recorder function
after the time set in this servo parameter has passed.
When "-1" is set, the drive recorder function is disabled.
When "0" is set, the drive recorder function will be switched after 600 s (10 min).
When any value of "1" to "9" is set, the drive recorder function will be switched after 10 s.
When any value of "10" to "32767" is set, the drive recorder function will be switched after the time set in this servo parameter
has passed.
[Pr. PF23_Vibration tough drive - Oscillation detection level
(OSCL1)]
Initial value
20 [%]
Set the oscillation detection level for readjusting the machine resonance suppression filter while the vibration tough drive is
enabled.
When the oscillation level is higher than the setting value of this servo parameter, reset [Pr. PB13 Machine resonance
suppression filter 1] or [Pr. PB15 Machine resonance suppression filter 2].
When "0" is set, the oscillation detection level is 20 %.

[Pr. PF24_Function selection F-9 (*FOP9)]

Initial value
00000000h
[Pr. PF24.0_Oscillation detection alarm selection]
Initial value
0h
Select the alarm output at oscillation detection.
Select whether to generate an alarm or a warning when an oscillation continues at a level set in [Pr. PF23 Vibration tough
drive - Oscillation detection level].
This function is enabled regardless of the setting of [Pr. PA20.1 Vibration tough drive selection].
0: Alarm ([AL. 054 Oscillation detection])
1: Warning ([AL. 0F3.1 Oscillation detection warning])
2: Oscillation detection function disabled (oscillation detection not processed)
Setting range
-1 to 32767
Setting range
0 to 100
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting method
Common
Setting method
Each axis
Setting method
Each axis
Ver.
C4
1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
Ver.
C4
Ver.
C4
Ver.
Refer to the relevant detail No.
1