[Pr. Pa02_Regenerative Option (**Reg)] - Mitsubishi Electric MELSERVO MR-J5W-B Series User Manual

Hide thumbs Also See for MELSERVO MR-J5W-B Series:
Table of Contents

Advertisement

[Pr. PA02_Regenerative option (**REG)]

Initial value
00000000h
[Pr. PA02.0-1_Regenerative option selection]
Initial value
00h
Select a regenerative option.
Incorrect setting may cause the regenerative option to burn.
If a selected regenerative option is not for use with the servo amplifier, [AL. 037 Parameter error] occurs.
Other regenerative options cannot be used together with the FR-XC-(H).
00: Regenerative option is not used.
• No regenerative resistors are used on servo amplifiers with a capacity of 100 W.
• Built-in regenerative resistors are used on servo amplifiers with a capacity of 0.2 kW to 7 kW.
01: FR-XC-(H)
02: MR-RB032
03: MR-RB12
05: MR-RB30
06: MR-RB50 (A cooling fan is required.)
08: MR-RB31
09: MR-RB51 (A cooling fan is required.)
0B: MR-RB3N
0C: MR-RB5N (A cooling fan is required.)
0D: MR-RB14
0E: MR-RB34
1C: MR-RB3Z
1D: MR-RB5Z (A cooling fan is required.)
80: MR-RB1H-4
81: MR-RB3M-4 (A cooling fan is required.)
82: MR-RB3G-4 (A cooling fan is required.)
83: MR-RB5G-4 (A cooling fan is required.)
93: MR-RB3Y-4 (A cooling fan is required.)
94: MR-RB5Y-4 (A cooling fan is required.)
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting method
Common
Ver.
C4
1 SERVO PARAMETER DETAILS
1.2 Basic setting servo parameters group ([Pr. PA_ _ ])
Ver.
Refer to the relevant detail No.
1
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j5-b series

Table of Contents