[Pr. PB48_Machine resonance suppression filter 4 (NH4)]

Initial value
4500 [Hz]
Set the notch frequency of the machine resonance suppression filter 4.
When [Pr. PB49.0 Machine resonance suppression filter 4 selection] is set to "1" (enabled), set the notch frequency with this
servo parameter.

[Pr. PB49_Notch shape selection 4 (NHQ4)]

Initial value
00000000h
Set forms of the machine resonance suppression filter 4.
[Pr. PB49.0_Machine resonance suppression filter 4 selection]
Initial value
0h
0: Disabled
1: Enabled
When this setting value is "Enabled", [Pr. PB17 Shaft resonance suppression filter] cannot be used.
[Pr. PB49.1_Notch depth selection]
Initial value
0h
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
[Pr. PB49.2_Notch width selection]
Initial value
0h
0: α = 2
1: α = 3
2: α = 4
3: α = 5
Setting range
10 to 9000
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
Refer to the text
Setting method
Each axis
Setting method
Each axis
Ver.
C4
Ver.
C4
Ver.
C4
1 SERVO PARAMETER DETAILS
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
Ver.
C4
Ver.
Refer to the relevant detail No.