Power Supply Through The Pre-Assembled Mains Connection Cable; Power Supply Without The Pre-Assembled Mains Connection Cable; Fig. 22: Removal Of The Controller From The Lower Shell - oventrop Regumaq X-45 Operating Instructions Manual

Hide thumbs Also See for Regumaq X-45:
Table of Contents

Advertisement

Regumaq X-45
Commissioning
7.3.1
Power supply through the pre-
assembled mains connection cable
A fused earthed socket must be available at the
installation location.
f
Close the thermal insulation of the station by fi tting the
upper shell.
f
Insert the plug of the pre-assembled mains connection
cable into an earthed socket.
7.3.2
Power supply without the pre-
assembled mains connection cable
If the pre-assembled earthing contact plug cannot
be used, the power supply may only be estab-
lished by a qualifi ed electrician.
DANGER
Danger to life due to electric current!
There is a danger to life if live components are
touched.
!
Disconnect the product from the power supply
at all poles.
!
Check that no voltage is present.
!
Secure the product against being switching
back on again.
!
Only install the product in dry indoor areas.
NOTICE
Damage to electronic components due to
electrostatic discharge!
!
Before touching the inside of the casing,
ensure that the potentials are equalised by
taking suitable measures. Touch an earthed
component. This can be a water tap or a
radiator, for example..
Make sure that the product can be disconnected
from the power supply at any time.
f
Install a switch that is accessible at all times. Das It
must be possible to disconnect the product from
the mains at all poles via an additional device with
an isolating distance of at least 3 mm or with a
disconnecting device (fuse) in accordance with
applicable installation regulations.
The controller holder in the lower shell is designed in such
a way that you can easily fi x the controller in a comfortable
mounting position without tools.
30
1
Carefully pull the controller off the lower shell as
shown in Fig. 22 on page 30.
NOTICE
Damage to the electrical lines and connections
due to tensile forces!
Electrical lines or connections can break if
excessive tensile forces are applied.
!
Make sure that the cables connected to the
controller are not subjected to strain.
Fig. 22:
Removal of the controller from the lower shell
2
Turn the controller and fi x it in the mounting position
as shown in Fig. 23 on page 31.