Omron SYSMAC CS1W-CLK11 Operation Manual page 265

Table of Contents

Advertisement

Status Area and Troubleshooting
Other Status
Bit status
Error log exists (IR 19015)
is 1: ON
Communications controller
send error (IR 19011) is 1:
ON
Inconsistent network
parameters (IR 19010) is 1:
ON
Node address duplicate
setting error (IR 19009) is
1: ON
EEPROM error (IR 19007)
is 1: ON
PC system setting error (IR
19003) is 1: ON
Routing table error
(IR 19002) is 1: ON
Data link table error
(IR 19001) is 1: ON
Probable cause
Error information on the
Controller Link Unit (an
error log) has been
recorded.
The Controller Link Unit is
faulty.
Indicates that the network
parameters recorded in the
CPU Unit's EEPROM differ
from the values of the Net-
work in use.
The same node address
has been used more than
once.
An error has occurred
while writing data to the
CPU Unit's EEPROM.
The EEPROM data is dam-
aged.
The routing table data
within the CPU Unit's
EEPROM is damaged.
There is an error in the
routing table setting.
The data link table data in
the EEPROM of the CPU
Unit is damaged.
There is an error in the
data link table settings.
Section 9-2
Probable remedy
Using the Controller Link
Support Software or an
FINS command, read the
cause of the current error.
Alternatively, use past error
log records to troubleshoot
the problem.
Replace the Controller Link
Unit.
Check the network param-
eters on the Network in
use using the Controller
Link Support Software, and
reset necessary parame-
ters.
Reset so that each node
address is used only once
within the same Network.
Check the status of bits
IR 19000 to IR 19002 and
correct any problems
found. If the error occurs
again, replace the CPU
Unit.
Check the status of bits
IR 19000 to IR 19002 and
correct any problems
found. If the error occurs
again, replace the CPU
Unit.
Refer to 7-4 Setting Rout-
ing Tables and reset the
routing tables correctly. If
the error occurs again,
replace the Controller Link
Unit.
When using a routing
table, refer to 7-4 Setting
Routing Tabless and reset
the routing tables correctly.
If no routing tables are
being used, delete the
tables.
Refer to 5-3 Starting and
Stopping Data Links and
reset the data link tables
correctly. If the error occurs
again, replace the CPU
Unit.
When using manually set
data links, refer to 5-3
Starting and Stopping Data
Links and remake and set
the data link tables cor-
rectly. When manually set
data links are not being
used, delete the data link
tables.
249