Setfactor## ­ Set The Exposure Factor - Feasa 3D User Manual

Display analyser
Table of Contents

Advertisement

FEASA DISPLAY ANALYSER
FUNCTIONAL VERSION
Set Data Mode
SetFACTOR##
- Set the Exposure Factor
Transmit
Receive
Setfactor##
OK
Where:
##
represents the Factor Number and is in the range 01 – 15 (default 01).
Description
This command allows the user to adjust the Exposure Factor for all Fibers.
This is useful when it is required to test very dim LED's. The Factory default
setting is 01. The value can be adjusted from 01 to 15. The exposure time will
be increased when the factor is increased which will lead to longer test times
i.e. Factor 02 will double the test time, factor 03 will treble the test time etc.
Try the low range(capture1) first before adjusting the Exposure Factor.
These values are stored permanently in memory and can only be changed by
using the setFactor command again, power on/off will NOT effect the set Factor.
The current value can be read out using the
getfactor
command.
Example:
Set the Factor Number for all Fibers to 05.
setfactor05
OK