Parameter
Continuous output power
Surge power
Surge current when power
on
Output voltage
Output frequency
Output wave
Output distortion THD
Load power factor
Rated input voltage
Input voltage range
Rated output efficiency
Max. output efficiency
Idle current
No-load current
RS485 com. port
Mechanical parameters
Input terminal
Dimension (L x W x H)
Mounting size
Mounting hole size
Net Weight
① The "Surge current when power on" parameter is for the customized products with an anti-surge function (whose product model has "S"). For
other products, the actual surge current prevails.
IPT3000-12
IPT3000-22
3000W@35℃@Rated input voltage
6000W@5S
< 100A
12VDC
10.8 ~ 16.0VDC
21.6 ~ 32.0VDC
> 87.0%
> 90.0%
> 94.0% (30% loads)
> 94.0% (30% loads)
< 0.2A
< 1.6A
M10
557 × 228 × 118mm
521 × 270 × 143mm
532 × 145mm
495 × 145mm
Φ6mm
9.5kg
IPT3000-42
< 100A
< 65A
220VAC (± 3%); 230VAC (-6%~+3%); 240VAC (-9%~+3%)
50/60Hz ± 0.2%
Pure Sine Wave
THD ≤ 3% (Resistive load)
0.2 ~ 1 (Load power ≤ Continuous output power)
24VDC
48VDC
43.2 ~ 64.0VDC
> 92.5%
> 94.5% (30% loads)
< 0.15A
< 0.1A
< 1.0A
< 0.5A
5VDC/200mA
M6
M6
491 × 228 × 118mm
465 × 145mm
Φ6mm
Φ6mm
8.5kg
6.8kg
38
IPT4000-42
4000W@35℃@Rated
5000W@35℃@Rated
input voltage
input voltage
8000W@5S
< 65A
48VDC
43.2 ~ 64.0VDC
> 91.0%
> 94.0%(30% loads)
< 0.1A
< 0.6A
M6
516 × 228 × 118mm
531 × 228 × 118mm
490 × 145mm
505 × 145mm
Φ6mm
7.8kg
IPT5000-42
< 0.1A
< 0.8A
M6
Φ6mm
8.5kg