Epever IPT Series User Manual page 26

Pure sine wave inverter
Hide thumbs Also See for IPT Series:
Table of Contents

Advertisement

Step3: Press
for 2s to enter the configuration interface of the specified parameter.
Step4: Click
or
Step5: Press
for 2s to confirm the configuration.
Step6: Click
+
Parameters user define:
Display
Output voltage class
Output frequency class
Power Saving Enable
Low voltage disconnect
Low voltage reconnect
Over voltage reconnect
Over voltage disconnect
① After configuring the parameters marked with ①, the inverter will restart automatically. It will
resume work according to the new parameter value.
② Due to the length limit of the LCD displayed data. When the baud rate is set to 115200, the
to configure the parameter value.
to exit the current interface.
Parameters
LCD backlight time
Power Saving In
Power Saving Out
Baud Rate Select
voltage
voltage
voltage
voltage
Default
220VAC
110VAC
220/230/240VAC:
50Hz
100/110/120VAC:
60Hz
30s
OFF
20VA
40VA
(20VA + PSI) ~ (50%*rated power)
115200
12V: 10.5V~14.2V; step size 0.1V
12V: 10.8V
24V: 21.6V
48V: 43.2V
12V: 11.5V~15.2V; step size 0.1V
12V: 12.5V
24V: 25V
48V: 50V
12V: 11.5V~15.2V; step size 0.1V
12V: 14.5V
24V: 29V
48V: 58V
12V: 10.5V~14.2V; step size 0.1V
12V: 16V
24V: 32V
48V: 64V
23
User define
220VAC/230VAC/240VAC
100VAC/110VAC/120VAC
50Hz/60Hz
30s/ 60s/100s(ON solid)
ON/OFF
20VA ~ (20%*rated power)
9600/115200
24V: 21V-30.2V; step size 0.1V
48V: 42V-62.4V; step size 0.1V
24V: 22V-31.2V; step size 0.1V
48V: 43V-63.4V; step size 0.1V
24V: 22V-31.2V; step size 0.1V
48V: 43V-63.4V; step size 0.1V
24V: 21V-30.2V; step size 0.1V
48V: 42V-62.4V; step size 0.1V