Mounting size
Mounting hole size
Net Weight
① The "Surge current when power on" parameter is for the customized products with an anti-surge function (whose product model has "S"). For
other products, the actual surge current prevails.
② It means the rated output efficiency when the load power equals the "continuous output power" under the rated DC input voltage.
③ It means the max. output efficiency when the inverter is connected with different loads under the rated DC input voltage.
Parameter
Continuous
output
power
Surge power
Surge current when power
①
on
Output voltage
Output frequency
Output wave
Output distortion THD
Load power factor
Rated input voltage
Input voltage range
②
Rated output efficiency
③
Max. output efficiency
Idle current
No-load current
205 × 75mm
Φ5mm
1.5kg
IPT1000-11
IPT1000-21
1000W@35℃@Rated input voltage
2000W@5S
< 100A
THD ≤ 4% (Resistive
THD ≤ 3% (Resistive
load)
12VDC
10.8 ~ 16.0VDC
21.6 ~ 32.0VDC
> 87.0%
> 92.0% (40% loads)
> 92.5% (30% loads)
< 0.2A
< 0.8A
IPT1500-11
< 100A
100VAC/110VAC (± 3%); 120VAC (-7%~+3%)
50/60Hz ± 0.2%
Pure Sine Wave
load)
0.2 ~ 1 (Load power ≤ Continuous output power)
24VDC
12VDC
10.8 ~ 16.0VDC
> 90.0%
> 86.0%
> 93.0% (30% loads)
< 0.15A
< 0.2A
< 0.6A
< 1.0A
31
262 × 75mm
Φ5mm
2.3kg
IPT1500-21
1500W@35℃@Rated input voltage
3000W@5S
< 100A
THD ≤ 4% (Resistive load)
24VDC
21.6 ~ 32.0VDC
> 88.0%
> 92.5% (30% loads)
< 0.15A
< 0.9A
IPT1500-41
< 50A
48VDC
43.2 ~ 64.0VDC
> 90.0%
> 92.0% (30% loads)
< 0.1A
< 0.5A