Epever IPT Series User Manual page 34

Pure sine wave inverter
Hide thumbs Also See for IPT Series:
Table of Contents

Advertisement

Mounting size
Mounting hole size
Net Weight
① The "Surge current when power on" parameter is for the customized products with an anti-surge function (whose product model has "S"). For
other products, the actual surge current prevails.
② It means the rated output efficiency when the load power equals the "continuous output power" under the rated DC input voltage.
③ It means the max. output efficiency when the inverter is connected with different loads under the rated DC input voltage.
Parameter
Continuous
output
power
Surge power
Surge current when power
on
Output voltage
Output frequency
Output wave
Output distortion THD
Load power factor
Rated input voltage
Input voltage range
Rated output efficiency
Max. output efficiency
Idle current
No-load current
205 × 75mm
Φ5mm
1.5kg
IPT1000-11
IPT1000-21
1000W@35℃@Rated input voltage
2000W@5S
< 100A
THD ≤ 4% (Resistive
THD ≤ 3% (Resistive
load)
12VDC
10.8 ~ 16.0VDC
21.6 ~ 32.0VDC
> 87.0%
> 92.0% (40% loads)
> 92.5% (30% loads)
< 0.2A
< 0.8A
IPT1500-11
< 100A
100VAC/110VAC (± 3%); 120VAC (-7%~+3%)
50/60Hz ± 0.2%
Pure Sine Wave
load)
0.2 ~ 1 (Load power ≤ Continuous output power)
24VDC
12VDC
10.8 ~ 16.0VDC
> 90.0%
> 86.0%
> 93.0% (30% loads)
< 0.15A
< 0.2A
< 0.6A
< 1.0A
31
262 × 75mm
Φ5mm
2.3kg
IPT1500-21
1500W@35℃@Rated input voltage
3000W@5S
< 100A
THD ≤ 4% (Resistive load)
24VDC
21.6 ~ 32.0VDC
> 88.0%
> 92.5% (30% loads)
< 0.15A
< 0.9A
IPT1500-41
< 50A
48VDC
43.2 ~ 64.0VDC
> 90.0%
> 92.0% (30% loads)
< 0.1A
< 0.5A

Advertisement