Surge power
Surge current when power
①
on
Output voltage
Output frequency
Output wave
Output distortion THD
Load power factor
Rated input voltage
Input voltage range
②
Rated output efficiency
③
Max. output efficiency
Idle current
No-load current
RS485 com. port
Mechanical parameters
Input terminal
Dimension (L x W x H)
Mounting size
Mounting hole size
Net Weight
① The "Surge current when power on" parameter is for the customized products with an anti-surge function (whose product model has "S"). For
other products, the actual surge current prevails.
② It means the rated output efficiency when the load power equals the "continuous output power" under the rated DC input voltage.
③ It means the max. output efficiency when the inverter is connected with different loads under the rated DC input voltage.
< 100A
220VAC (± 3%); 230VAC (-6%~+3%); 240VAC (-9%~+3%)
THD ≤ 3% (Resistive load)
0.2 ~ 1 (Load power ≤ Continuous output power)
12VDC
10.8 ~ 16.0VDC
> 88.0%
> 94.0% (30% loads)
< 0.2A
< 1.2A
M10
420 × 228 × 118mm
395 × 145mm
Φ6mm
7.0kg
4000W@5S
< 100A
50/60Hz ± 0.2%
Pure Sine Wave
24VDC
21.6 ~ 32.0VDC
> 90.0%
> 93.0% (30% loads)
< 0.15A
< 1.0A
5VDC/200mA
M6
421 × 228 × 118mm
395 × 145mm
Φ6mm
5.8kg
37
< 50A
48VDC
43.2 ~ 64.0VDC
> 92.5%
> 94.5% (30% loads)
< 0.1A
< 0.5A
M6
421 × 228 × 118mm
395 × 145mm
Φ6mm