RS485 port
Mechanical parameters
Input terminal
Dimension (L x W x H)
Mounting size
Mounting hole size
Net Weight
① The "Surge current when power on" parameter is for the customized products with an anti-surge function (whose product model has "S"). For
other products, the actual surge current prevails.
② It means the rated output efficiency when the load power equals the "continuous output power" under the rated DC input voltage.
③ It means the max. output efficiency when the inverter is connected with different loads under the rated DC input voltage.
Parameter
Continuous output power
Surge power
Surge current when power
on
Output voltage
Output frequency
Output wave
Output distortion THD
Load power factor
Rated input voltage
Input voltage range
Rated output efficiency
M6
371 × 228 × 118mm
345 × 145mm
Φ6mm
4.8kg
IPT2000-11
2000W@35℃@Rated input voltage
< 100A
100VAC/110VAC (± 3%); 120VAC (-7%~+3%)
THD ≤ 5% (Resistive
THD ≤ 4% (Resistive load)
load)
0.2 ~ 1 (Load power ≤ Continuous output power)
12VDC
10.8 ~ 16.0VDC
> 85.0%
5VDC/200mA
IPT2000-21
4000W@5S
< 100A
50/60Hz ± 0.2%
Pure Sine Wave
THD ≤ 4% (Resistive load)
24VDC
21.6 ~ 32.0VDC
> 88.0%
32
M6
387 × 228 × 118mm
361 × 145mm
Φ6mm
5.6kg
IPT2000-41
< 50A
48VDC
43.2 ~ 64.0VDC
> 88.0%