RS485 port
Mechanical parameters
Input terminal
Dimension (L x W x H)
Mounting size
Mounting hole size
Net Weight
① The "Surge current when power on" parameter is for the customized products with an anti-surge function (whose product model has "S"). For
other products, the actual surge current prevails.
② It means the rated output efficiency when the load power equals the "continuous output power" under the rated DC input voltage.
③ It means the max. output efficiency when the inverter is connected with different loads under the rated DC input voltage.
Parameter
Continuous output power
Surge power
Surge current when power
①
on
Output voltage
Output frequency
Output wave
Output distortion THD
Load power factor
Rated input voltage
Input voltage range
②
Rated output efficiency
M6
371 × 228 × 118mm
345 × 145mm
Φ6mm
4.8kg
IPT2000-11
2000W@35℃@Rated input voltage
< 100A
100VAC/110VAC (± 3%); 120VAC (-7%~+3%)
THD ≤ 5% (Resistive
THD ≤ 4% (Resistive load)
load)
0.2 ~ 1 (Load power ≤ Continuous output power)
12VDC
10.8 ~ 16.0VDC
> 85.0%
5VDC/200mA
IPT2000-21
4000W@5S
< 100A
50/60Hz ± 0.2%
Pure Sine Wave
THD ≤ 4% (Resistive load)
24VDC
21.6 ~ 32.0VDC
> 88.0%
32
M6
387 × 228 × 118mm
361 × 145mm
Φ6mm
5.6kg
IPT2000-41
< 50A
48VDC
43.2 ~ 64.0VDC
> 88.0%