Step 2: Determine the installation location and heat-dissipation space
The inverter shall be installed in a place with sufficient airflow through the dissipation pad of the inverter.
And a minimum clearance of 150mm from the upper and lower edges of the inverter is recommended to
ensure natural thermal convection. The following takes IPT3000-1x as an example.
It is not recommended to install the product in an enclosed cabinet, where the device
cooling will be influenced. If mounted in an enclosure cabinet, ensure effective
ventilation and not turn on all loads. Or else the device over temperature protection is
CAUTION
caused.
Step3: Wiring
 Turn off the inverter switch before wiring.
 Please do not connect the circuit breaker or fuse during the wiring and ensure that
the poles' leads are connected correctly.
CAUTION
 The terminals and ports on the side vary from the product models.
Wiring sequence (The following wiring sequence is illustrated in the appearance"IPT3000-11", wiring
positions of other inverters. Please refer to chapter
1.
Ground connection
The wire size for the ground connection must be thicker or equal to that for the AC output. Refer to
chapter
5.2 Wire size and circuit breaker
2 Appearance
for detailed wire size.
16
for reference.)