PSEN op2H-SL Series

Cascaded safety light grid

Use the cables stated in the
Legend
[1] Connection to master unit, cascading adapter, 5-pin
[2] Connection to slave unit, M12, 5-pin, female socket
1. Install the master unit and slave unit(s). See
2. Loosen the screws [1] on the cover of the cascading adapter and remove the cover.
Legend
[1] Fixing screws on the cover of the cascading adapter
3. Connect the 5-pin cascading adapter on the cable PSEN op SL cascading to the cas-
cading adapter on the master unit and the 5-pin female socket to the slave unit.
4. Re-attach the cover of the cascading adapter and tighten both screws to 0,2 Nm.
Operating Manual PSEN op2H-SL Series
1004304-EN-01
Order references for accessories [
[1]
[1]
51].
[2]
Installation [