Scope; Safety; Intended Use - Pilz PSEN op2H-SL Series Manual

Table of Contents

Advertisement

PSEN op2H-SL Series

Scope

Quant-
ity
1
1
4/6
4

Safety

Intended use

Safety light grids of the PSEN op2H-SL Series are electrosensitive protective equipment of
the 2. They are used to protect personnel and systems. The safety light grids are designed
for
securing hazardous areas within buildings and
}
securing access within buildings with a resolution of 24 mm.
}
The safety light grid may only be used for personal protection on machinery if
the hazardous state can be removed by the safety light grid and
}
the starting of the machine is controlled by the safety light grid and
}
the safety assessment prescribes no better resolution than 24 mm.
}
The safety level PL c (Cat. 2 )/SIL CL 1 is only achieved if
the safety outputs use 2-channel processing.
}
Operating Manual PSEN op2H-SL Series
1004304-EN-01
Description
Transmitter
Receiver
C-bracket
}
with slotted hole
washer and hexagon
socket cylinder head
screws 2 x M4x10 DIN
7984, 1 x M3x8 DIN
EN ISO 12474
4 brackets for protec-
ted field height
150 mm – 540 mm
6 brackets for protec-
ted field height
600 mm – 1200 mm
2 O-brackets
}
with washer and
hexagon socket cylin-
der head screw M4x10
DIN 7984
Illustration
8