Use separate cables to connect the wires to the OSSDs on different safety light grids or
}
safety switches.
For supply voltage, use only PELV/SELV power supplies that have a voltage buffer in
}
accordance with EN 60204-1.
The power supply must be able to bridge a short (20 ms) supply voltage failure in ac-
}
cordance with EN 61496-1.
The protection type (see
}
Pilz connection leads available as an accessory.
Connection to evaluation devices
}
Ensure compliance with permissible cable bending radii (see
}
details [

Connector pin assignment

Transmitter and receiver electrical connections are made with M12 connectors. These con-
nectors are located on the bottom of the transmitters and receivers.
Ensure that the wiring has been performed as indicated.
}
5-pin connector on the transmit-
ter
5-pin connector on the receiver
Operating Manual PSEN op2H-SL Series
1004304-EN-01
Technical details [
Use the cables listed in the order reference (see
accessories [
51])
The clamps for connection to the evaluation device must be kept in a locked control
cabinet. This prevents unauthorised modifications.
43]).
2
1
5
3
4
2
1
5
3
4
43]) can only be achieved by using the
Order references for
PIN
Assignment
1
+24 VDC
2
Restart
Configuration of the type of
restart or activation of align-
ment mode
3
0 VDC
4
Reserved
5
Start button
PIN
Assignment
1
+24 VDC
2
OSSD 1
3
0 VDC
4
OSSD 2
5
EDM
Activation/deactivation of
EDM function
Technical
Cable colour
brown
white
blue
black
grey
Cable colour
brown
white
blue
black
grey