Safety; Intended Use - Pilz PSEN sl-1.0p 2.2 Operating Manual

Hide thumbs Also See for PSEN sl-1.0p 2.2:
Table of Contents

Advertisement

BA PSEN sl­1.0p 1.1/1.1 VA/2.1/2.2

Safety

Intended use
The safety gate system meets the requirements in accordance with
}
EN 60204­1:2006
}
EN 60947­5­3:2005: PDF­M with the corresponding actuator PSEN sl­1.0 or PSEN
sl­1.0fm (see Technical details: System with normal actuator [
System with free­moving actuator [
}
EN 62061:2005: SIL CL 3
}
EN ISO 13849­1:2008: PL e and Cat. 4
}
The safety switch may only be used with the corresponding actuator (see Technical de­
tails: System with normal actuator, [
actuator [
The safety level PL e (Cat. 4 )/SIL CL 3 is only achieved if
}
the safety outputs use 2­channel processing.
The following is deemed improper use in particular:
}
Any component, technical or electrical modification to the product
}
Use of the product outside the areas described in this manual
}
Use of the product outside the technical details (see chapter entitled "Technical De­
tails").
Operating Manual BA PSEN sl­1.0p 1.1/1.1 VA/2.1/2.2
21909­EN­09
INFORMATION
This gives advice on applications and provides information on special fea­
tures.
 28], under mechanical data).
NOTICE
EMC­compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in­
terference.
INFORMATION
The magnet surface and counterplate may heat up. When installing, make
sure that heat dissipation is guaranteed.
 28], under mechanical data)
 25], Technical detail: System with free­moving
 25], Technical detail: