Cascaded Safety Light Grid; Wiring; General Guidelines - Pilz PSEN op2H-SL Series Manual

Table of Contents

Advertisement

PSEN op2H-SL Series
Legend
[1] Distance from the non-connection end of the safety light grid to the position of the
[2] 2 M4 screws to attach the L-bracket
[3] M4 screw to attach the C-bracket
[4] Position the safety light grid in the C-bracket at a slight angle
[5] Push the safety light grid in the L-bracket as far as it will go
[6] M3 screw to position the clamping jaw of the C-bracket
[7] Attach the horizontal section of the L-bracket to the vertical section using M3

Cascaded safety light grid

Transmitters and receivers on cascaded safety light grids are correctly aligned in exactly
the same way as a single safety light grid is aligned.
Start the alignment with the master unit and then continue with the slave unit (when there
are two slave units, start with the first slave unit and then the second slave unit).

Wiring

General guidelines

Do not lay the connecting cable near or in contact with cables that carry high or highly
}
volatile currents.
Operating Manual PSEN op2H-SL Series
1004304-EN-01
C-bracket at the non-connection end = ¼ of the protected field height
screws
[3]
[6]
[4]
[2]
[7]
[5]
29