Legend
[1] Reflective surface
[2] Transmitter
[3] Receiver
[4] Half of the
[5] Minimum distance D between the safety light grid and the reflective surface
[6] Passive reflections on the surface
[7] Distance between transmitter and receiver (working distance)
[8] Hazardous area
The minimum distance D depends on two factors:
Working distance between transmitter and receiver
}
the maximum
}
at:
5° = ± 2.5° in relation to the optical axis
Minimum distance of the safety light grid to reflective surfaces
The formula for calculating the minimum distance D is:
For a working distance of less than 3 m: D = 0.131 m
}
For a working distance of 3 m or more: D = working distance in m x tan ⍺
}
Operating Manual PSEN op2H-SL Series
1004304-EN-01
[4]
[2]
[4]
opening angle [
light grid
opening angle [
[1]
[1]
(= ⍺) of the light beams emitted by the safety
43]
43]
of the light beams emitted by the safety light grid
[5]
[4]
[3]
[4]
[5]
16