PSEN op2B/1 Series PSEN sensor technology Operating Manual-1003357-EN-02...
Page 2
Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
Use of deviating mirrors Use of the muting function Section 6 Installation and wiring Attach safety light grid without muting sensors to mounting surface Conversion of safety light grids without muting sensors Installation of external muting sensors Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 4
Daily check 9.1.3 Check after plant/machine modification Maintenance Section 10 Dimensions Section 11 Technical details 11.1 Safety characteristic data Section 12 Order reference 12.1 Order reference for safety light grids 12.2 Order reference for accessories Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 5
Content Section 13 Attachment 13.1 Check list Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Introduction Introduction Validity of documentation This documentation is valid for the product PSEN op2B/1 Series. It is valid until new docu- mentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
Page 7
Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Features of the safety light grid Type 2 Safeguards protected fields with body resolution Muting All safety light grids in the PSEN op2B/1 Series are able to process data from connec- ted muting sensors Infrared protected field is generated Transmitter and receiver are synchronised optically...
Order reference Description PSEN op2.1 L-Muting Set L-muting sensors to retrofit PSEN op muting bracket kit Mounting bracket for one muting sensor PSEN op cable M12 4-p. 0.75m Connection cable for L-muting, L-muting 4‑core, shielded Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Scope Safety light grid with body resolution, without integrated muting sensors Order reference Description PSEN op2B-2-050/1 or Safety light grid, consisting of PSEN op2B-3-080/1 or Transmitter, PSEN op2B-4-090/1 or Receiver PSEN op4B-4-120/1 Mounting kit Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Safety Safety Intended use Safety light grids in the PSEN op2B/1 Series constitute electrosensitive protective equip- ment. They are used to protect personnel and plants. The safety light grids are designed to Safeguards protected fields with body resolution Safeguard danger zones and Safeguard access.
In safety-related applications, please comply with the mission time T in the safety-re- lated characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSEN op2B/1 Series 1003357-EN-02...
LED indicators. During the installation phase, two yellow LEDs simplify the alignment of the two units. The indicators are described under: Status information during operation [ LED support during alignment [ Indicators for fault diagnostics Operating Manual PSEN op2B/1 Series 1003357-EN-02...
It must not be possible to operate the pushbutton from inside the danger zone. The button must be located at a position from which there is a full, un- obstructed view of the danger zone. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
In order to restore normal operating con- ditions, the safety light grid must be reset. Internal errors are: Malfunction of the outputs or Optical malfunction or Malfunction of the muting display or Incorrect operation of the EDM function. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
If a malfunction is de- tected, the safety light grid switches to a safe condition and stops the connected machine. This check is carried out each time the OSSD is triggered and before restarting. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Muting proves to be particularly suitable when, under certain operating conditions, an object is permitted to pass through the danger zone but a person is not. The following diagrams illustrate application examples for the three product types. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 18
Function description Fig.: Muting in one direction: Expansion with L-muting set Fig.: Muting in two directions: Expansion with T-muting set Operating Manual PSEN op2B/1 Series 1003357-EN-02...
– when the first sensor has detected a conveyed material and the second sensor also detects it max. 4 s afterwards. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 20
If the muting lamp is defective, the muting function cannot be activated. Any attempt to activate the function will immediately trigger the safety light grid and instantly switch off the OSSD; the muting lamp fault indicator will also light (seeIndicators for fault dia- gnostics). Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 21
: Once this time has elapsed, the muting function switches off automatically, max. 8 s Moff Input Muting 1 Input Muting 2 Muting function Fig.: Timing diagram for T-type muting Legend : Time from the activation of the first sensor to the activation of the second sensor, max. 4 s Operating Manual PSEN op2B/1 Series 1003357-EN-02...
If the muting sensors are still active after 10 minutes (status when delivered), the muting status is cancelled and the safety light grid switches to a safe condition. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Fig.: Timing diagram for override function A key or automatic reset button is provided for activation. Position the key or pushbutton so that when the override function is activated nobody can reach the danger zone and Operating Manual PSEN op2B/1 Series 1003357-EN-02...
The test function can be used to test the safety light grid. The reaction of the safety light grid corresponds to the reaction when a protected field is violated, but can be triggered by pressing the TEST/START button. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Fig.: Timing diagram for test function Convert type without muting set to L/T-type The safety light grids in the PSEN op2B/1 Series series are already capable of processing the data from muting sensors and can be upgraded to L or T-types using the muting sensors available as accessories.
Avoid strong electromagnetic interference when operating the safety light grid. When operating the safety light grid, avoid the development of smoke, mist and dust that would reduce the operating range of the safety light grid. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
10° = ± 5° in relation to the optical axis The formula for calculating the minimum distance D Operating range < 3 m: 0.27 m Operating range ≥ 3 m: 0.5 x D in m x tan 2α Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Fig.: Non-permitted layout of two adjacent safety light grids Positioning of several adjacent safety light grids: Both safety light grids must be oriented in opposite directions or An opaque surface must be positioned between two safety light grids. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
The diagram below shows an example solution for monitoring three different access sides using two deviating mirrors. The deviating mirrors must be positioned at an angle of 45° to the beams from the safety light grid. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 30
Please consider this reduction when positioning the safety light grid. You should not use more than three mirrors per device. Any dust or dirt on the mirror’s reflective surface will drastically reduce the operating range. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
The sign should indicate that there is no protection when the muting lamp is lit. Please note the following distances and times when installing the safety light grid and using the muting function. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 32
[1] Safety light grid A1 First muting sensor on the input side B1 Second muting sensor on the input side A2 First muting sensor on the output side B2 Second muting sensor on the output side Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 33
4.125 Speed at which the object is moving < D Distance must be Distance between the mut- MutingOff covered within 4 s ing sensors A1 and B1 Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 34
A1 to the second muting sensor Distance between activation of MutingOff the muting function and the position from which the muting function is switched off again Distances for cross muting with 2 sensors Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Requirement for installing the muting sensors on the safety light grid: The PSEN op muting bracket kit must be attached to both units of the safety light grid. The safety light grid must already be attached to the mounting surface. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Sensor B1, with transport in one direction Sensors A2 and B1, with transport in two directions As closely as possible to the safety light grid (see Distances between muting sensors in the application example - 4 muting sensors [ 32]). Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Input signal for second muting sensor White 3 0 VDC Supply voltage for external muting sensor Blue 4 Muting 1 Input signal for first muting sensor Black 5 n.c. Grey n.c. = not connected Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 38
Fig.: 4-pin connector on the transmitter to connect transmitter to supply voltage PIN Designation Description Cable colour 1 +24 VDC Supply voltage for transmitter Brown 2 n.c. White 3 0 VDC Supply voltage for transmitter Blue 4 n.c. Black Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Connect the N/C contact on the TEST/START button to the supply voltage on the safety light grid. 6.4.4 Connect the N/C contact on the EDM to the supply voltage on the safety light grid. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
For T-muting and for cross muting: PSEN op cableset The connection cable is used to Connect the muting sensors to the safety light grid Supply voltage to the muting sensors via the safety light grid. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Identify the earthing contact using the adhesive label provided. 6.4.7 Wiring of external sensors on the safety light grid Wire the external muting sensors in the control cabinet in accordance with the details stated under Connections for muting [ 40]. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
To use muting, the following requirements apply: the muting lamp must not be defective, the muting inputs must be wired correctly (see Connector pin assignment [ 37]), the safety light grid must be in normal operation. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Restart after unit is triggered Select how the restart is controlled after the OSSDs have been switched off. Without restart interlock Status when delivered With restart interlock Set DIP switches 4 and 8 to OFF. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Align [4] will light If both beams are aligned correctly and the LEDs are lit, the green LED will also light [1] The alignment of a type without muting set is described under Safety light grid alignment. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
If a single light beam is interrupted by an opaque object – the green LED must go out, – the red LED must light and – the safety light grid must switch to a safe condition. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Legend: [1]: Move the muting sensor upwards on the mounting profile for vertical alignment [2]: Move the muting sensor within the slot hole for horizontal alignment Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Maintaining the safety distance. If muting sensors are installed: Check that the muting sensors operate correctly. Access the protected field covered by the muting sensors. – The muting lamp on the safety light grid must light. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
This section provides information on how to connect the safety light grid to an evaluation device. A safety relay from the PNOZsigma series (PNOZ s4, PNOZ s5) can be used as the evalu- ation device, for example. The wiring is described in the operating instructions for the PNOZsigma device. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Normal Override can be performed. Opera- Activate the override function and tion make sure that the protected field is clear. OSSD Lights Restart/ Flashes Align yellow Align LED indicators during normal operation - Receiver Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Switch the safety light grid off and then on again. If the display is un- changed, swap the ex- ternal switching device. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 51
[ 56]) details [ 56]. green Switch the safety light grid off and then on Flashes again. yellow If the display is un- changed, contact Pilz. LED indicators in fault condition - Receiver Operating Manual PSEN op2B/1 Series 1003357-EN-02...
There must be nobody within the danger zone Procedure Press the TEST/START button for at least 5 seconds and then release it. The OSSDs switch on, the green LED lights and the connected machine starts up. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
The Appendix contains a Checklist which should help you perform the safety check. Maintenance Other than cleaning the lens covers, the safety light grids requires no other form of main- tenance. CAUTION! Improper cleaning agents can damage the safety light grid and lead to mal- functions Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 54
Moist cotton cloths should be used for cleaning. Avoid using Alcohol Solvents, Cloths made of wool, Cloths made of synthetic material. The lens covers should be cleaned during the daily check of hte safety light grid. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Dimensions Dimensions Safety light grid without integrated muting sensors M12x1 Fig.: Receiver M12x1 Fig.: Transmitter Legende [1] Height of protected field [2] Position of first light beam [3] Position of last light beam Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Shock stress In accordance with the standard EN 60068-2-29 EN 60068-2-29 Acceleration Duration 16 ms 16 ms Airgap creepage Pollution degree Protection type In accordance with the standard EN 60529 EN 60529 Housing IP65 IP65 Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 57
In accordance with the standard EN 60068-2-6 EN 60068-2-6 Frequency 10 - 55 Hz 10 - 55 Hz 0,35 mm 0,35 mm Amplitude Shock stress In accordance with the standard EN 60068-2-29 EN 60068-2-29 Acceleration Duration 16 ms 16 ms Operating Manual PSEN op2B/1 Series 1003357-EN-02...
A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 61
Mounting bracket for one muting sensor 630 824 PSEN op cable M12 4-p. 0.75m Connection cable for L-muting, 630 282 L-muting 4‑core, shielded PSEN op cableset Connection cable for T-muting, 630 295 4‑core, shielded Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 62
Has the minimum distance been calculated in accordance with the applicable stand- ards? Has the calculated minimum distance been maintained at all points? Check protected field Has the ability to creep underneath the pro- tected field undetected been excluded? Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 63
When you switch on, is it necessary to oper- ate the control device for the start-up inter- lock before the plant/machine can start up? Switch off safety light grid Is the hazardous movement stopped imme- diately when you switch off? Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 64
Check guard function for protected field of the safety light grid: Violate the protected field at various points: The hazardous movement must be shut down. Check that the start/restart interlock is work- ing correctly. Operating Manual PSEN op2B/1 Series 1003357-EN-02...
Page 65
Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland +41 62 88979-30 Mexico +43 1 7986263-0...