Character Conversion

Character conversion is an eight byte configuration item. The eight bytes are
4 character pairs represented in hexadecimal ASCII values. The first charac-
ter in the pair is the character that will be converted. The second character in
the pair is the character to convert to. If the character to convert in a pair is
FF, then no conversion is done.
For example, if you have the character conversion configuration item set to
the following: 41423132FFFFFFFF
The first pair is 4142 or AB (41 hex is an ASCII capital A, 42 hex is an ASCII
capital B) and the second pair is 3132 or 12 (31 hex is an ASCII 1, 32 is an
ASCII 2). The other two pairs are FFFF and FFFF.
With the label, AB12BA21, it would look as follows after the character con-
version: BB22BB22.
The A characters were converted to B characters and the 1 characters were
converted to 2 characters. Nothing is done with the last two character pairs,
since they are all FF.
To set Character Conversion:
1. Go to
2. Scan the "Configure Character Conversion" bar code.
3. Determine the desired string. Sixteen positions must be determined as
4. Turn to
5. Scan the ENTER/EXIT bar code to exit Programming Mode.
Product Reference Guide
page 61
and scan the ENTER/EXIT bar code.
in the above example. Next, turn to the
cover of this manual and find the equivalent hex digits needed to fulfill
the string.
Appendix D, Keypad
hex characters determined in the previous step.
If less than the expected string of 16 characters are selected, scan the
ENTER/EXIT bar code twice to accept the selections and exit Program-
ming Mode.
ASCII Chart
and scan the bar codes representing the
on the inside back