Keyboard Interface

Wedge Quiet Interval

Specifies the amount of time the reader looks for keyboard activity before it
breaks the keyboard connection in order to transmit data to host. The range
is from 0 to 990ms in 10ms increments.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad
3. Go to
4. Scan the bar code: SELECT WEDGE QUIET INTERVAL SETTING.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
This completes the procedure to set the Wedge Quiet Interval. See
for some examples of how to set this feature.
Table 35. Wedge Quiet Interval Setting Examples
STEP
ACTION
1
Desired Setting
Divide by 10 (and pad with
2
leading zeroes)
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT WEDGE QUIET INTERVAL SETTING
Scan Two Characters From
5
Appendix D, Keypad
6
Scan ENTER/EXIT PROGRAMMING MODE
278
This feature applies ONLY to the Keyboard Wedge interface.
the result with leading zeroes to yield two digits. For example: 0 = 00,
5 = 05, 20 = 20, etc.
page 42
and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Prog. Mode.
pad, that represent the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.
EXAMPLES
10ms
01
'0' and '1'
150ms
600ms
15
60
'1' and '5'
'6' and '0'
PowerScan™ PD953X/PBT950X/PM950X
Appendix D, Key-
Table 35
850ms
85
'8' and '5'